siRNA / miRNA gene silencing Human Primary Human Aortic Endothelial Cells GLO-1

- Found 9361 results

Get tips on using Monoclonal Mouse Anti-Human Hepatocyte (Concentrate) Clone OCH1E5 to perform Immunohistochemistry Mouse - Hepatocyte

Products Agilent Technologies Monoclonal Mouse Anti-Human Hepatocyte (Concentrate) Clone OCH1E5

Get tips on using Human/Mouse/Rat Activin A Quantikine ELISA Kit to perform ELISA Rat - Activin

Products R&D Systems Human/Mouse/Rat Activin A Quantikine ELISA Kit

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Human Point mutation SKOV3 humanized trastuzumab

Get tips on using 300 prep FavorPrep™ Plasmid DNA Extraction Mini Kit (sample size: 1~ 5 ml culture cells) to perform Plasmid Isolation Vibrio parahaemolyticus

Products Favorgen 300 prep FavorPrep™ Plasmid DNA Extraction Mini Kit (sample size: 1~ 5 ml culture cells)

As autophagy is a multi-step process which includes not just the formation of autophagosomes, but most importantly, flux through the entire system, including the degradation upon fusion with lysosomes, which makes it quite challenging for detection. There are several methods for detection in mammalian cells, including immunoblotting analysis of LC3 and p62 and detection of autophagosome formation/maturation by fluorescence microscopy, Currently, there is no single “gold standard” for determining the autophagic activity that is applicable in every experimental context, hence it is recommended to go for the combined use of multiple methods to accurately assess the autophagic activity in any given biological setting.

Cellular assays Autophagy assay cell type MT-2 (human T cell leukaemia)

Wound healing assay can be challenging due to inconsistencies and variations while making a wound on the confluent cell monolayer, consequently leads to wounds of varying sizes and widths. Moreover, this assay causes damage to the cells that are at the edge of the wound, which can prevent cell migration into the wound site and healing. The best solution is to use the standard wound healing assay kits using either combs or inserts to make a defined wound field or gap and prevent the well-to-well variation in these assays.

Cellular assays Wound healing assay cell type human MCF-7

Wound healing assay can be challenging due to inconsistencies and variations while making a wound on the confluent cell monolayer, consequently leads to wounds of varying sizes and widths. Moreover, this assay causes damage to the cells that are at the edge of the wound, which can prevent cell migration into the wound site and healing. The best solution is to use the standard wound healing assay kits using either combs or inserts to make a defined wound field or gap and prevent the well-to-well variation in these assays.

Cellular assays Wound healing assay cell type human Caco-2

Wound healing assay can be challenging due to inconsistencies and variations while making a wound on the confluent cell monolayer, consequently leads to wounds of varying sizes and widths. Moreover, this assay causes damage to the cells that are at the edge of the wound, which can prevent cell migration into the wound site and healing. The best solution is to use the standard wound healing assay kits using either combs or inserts to make a defined wound field or gap and prevent the well-to-well variation in these assays.

Cellular assays Wound healing assay cell type human epidermal keratinocytes

Wound healing assay can be challenging due to inconsistencies and variations while making a wound on the confluent cell monolayer, consequently leads to wounds of varying sizes and widths. Moreover, this assay causes damage to the cells that are at the edge of the wound, which can prevent cell migration into the wound site and healing. The best solution is to use the standard wound healing assay kits using either combs or inserts to make a defined wound field or gap and prevent the well-to-well variation in these assays.

Cellular assays Wound healing assay cell type human BxPC-3

Wound healing assay can be challenging due to inconsistencies and variations while making a wound on the confluent cell monolayer, consequently leads to wounds of varying sizes and widths. Moreover, this assay causes damage to the cells that are at the edge of the wound, which can prevent cell migration into the wound site and healing. The best solution is to use the standard wound healing assay kits using either combs or inserts to make a defined wound field or gap and prevent the well-to-well variation in these assays.

Cellular assays Wound healing assay cell type human RT-7

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms