Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
Get tips on using Quick Amp Labeling Kit-one color to perform Microarray RNA amplification & Labeling - Mouse cochlaea Cyanine CTP
Get tips on using Ovation® RNA Amplification System V2 to perform Microarray RNA amplification & Labeling - Mouse cochlaea Biotin
Get tips on using Anti-LC3B antibody produced in rabbit to perform Autophagy assay cell type - Mouse lung tissue
Get tips on using MagMAX™-96 Total RNA Isolation Kit to perform RNA isolation / purification Tissue - Rat Lung
Get tips on using mirVana™ miRNA Isolation Kit, with phenol to perform RNA isolation / purification Tissue - Mouse Lung
Get tips on using T-PER™ Tissue Protein Extraction Reagent to perform Protein isolation Tissue - Mouse lung tissue
Get tips on using KAPA Stranded RNA-Seq Kits with RiboErase (HMR) to perform RNA sequencing Rat - Lung tissue
Get tips on using Cell Counting Kit-8 to perform Cell cytotoxicity / Proliferation assay cell type - LTEP-a-2 lung adenocarcenoma
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment