siRNA / miRNA gene silencing Human SKOV-3

- Found 5734 results

Get tips on using CpGenome Universal DNA Modification Kit to perform DNA methylation profiling Gene specific profiling - Ca Ski HPV-16

Products Millipore CpGenome Universal DNA Modification Kit

Get tips on using Imprint® Methylated DNA Quantification Kit to perform DNA methylation profiling Gene specific profiling - MRC-5 LSH

Products Sigma-Aldrich Imprint® Methylated DNA Quantification Kit

Get tips on using Senescence β-Galactosidase Staining Kit - Beyotime to perform Reporter gene assay β-galactosidase substrates - rat nucleus pulposus

Products Beyotime Senescence β-Galactosidase Staining Kit - Beyotime

Get tips on using Senescence β-Galactosidase Staining Kit - Beyotime to perform Reporter gene assay β-galactosidase substrates - adipose stem cells

Products Beyotime Senescence β-Galactosidase Staining Kit - Beyotime

Get tips on using Senescence β-Galactosidase Staining Kit - Beyotime to perform Reporter gene assay β-galactosidase substrates - SK-Hep-1

Products Beyotime Senescence β-Galactosidase Staining Kit - Beyotime

Get tips on using Luminescent β-galactosidase Detection Kit II to perform Reporter gene assay β-galactosidase substrates - MDA-MB-231

Products Takara Bio Inc Luminescent β-galactosidase Detection Kit II

Get tips on using STEMdiff™ SMADi Neural Induction Kit to perform Stem cell Differentiation media Differentiation of Human iPSC into Human Neuroepithelial cells

Products STEMCELL technologies STEMdiff™ SMADi Neural Induction Kit

Get tips on using GenJet™ In Vitro DNA Transfection Reagent to perform DNA transfection Mammalian cells - Primary cells Human lung fibroblasts (HLF)

Products SignaGen Laboratories GenJet™ In Vitro DNA Transfection Reagent

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD45

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD11b

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms