Western blot 1,4 β-N-acetyl-D-glucosamine Triticum vulgaris Bacteria

- Found 7055 results

When extracting nucleic acids from cell cultures, thorough homogenization of cells via vortexing in lysis buffer is very necessary. Choose the best RNA isolation method keeping in mind the downstream applications, generally, column-based isolations result in clean and concentrated RNA samples. Downstream applications like sequencing and cDNA synthesis require high-quality RNA, always treat the samples with DNases and check their integrity by running a gel.

RNA RNA isolation / purification Cells primary human dermal fibroblasts

When extracting nucleic acids from cell cultures, thorough homogenization of cells via vortexing in lysis buffer is very necessary. Choose the best RNA isolation method keeping in mind the downstream applications, generally, column-based isolations result in clean and concentrated RNA samples. Downstream applications like sequencing and cDNA synthesis require high-quality RNA, always treat the samples with DNases and check their integrity by running a gel.

RNA RNA isolation / purification Cells primary rat dermal fibroblasts

When extracting nucleic acids from cell cultures, thorough homogenization of cells via vortexing in lysis buffer is very necessary. Choose the best RNA isolation method keeping in mind the downstream applications, generally, column-based isolations result in clean and concentrated RNA samples. Downstream applications like sequencing and cDNA synthesis require high-quality RNA, always treat the samples with DNases and check their integrity by running a gel.

RNA RNA isolation / purification Cells primary bovine monocyte derived macrophages

Get tips on using NEBNext® Ultra™ Directional RNA Library Prep Kit for Illumina® to perform RNA sequencing Mouse - ESCs (Embryonic Stem Cells)

Products New England BioLabs NEBNext® Ultra™ Directional RNA Library Prep Kit for Illumina®

Get tips on using GeneChip® HT 3' IVT PLUS Reagent Kit to perform Microarray RNA amplification & Labeling - Human endometrial stromal cells Biotin

Products Thermo Fisher Scientific GeneChip® HT 3' IVT PLUS Reagent Kit

Get tips on using GeneChip® Human Genome U133 Plus 2.0 Array to perform Microarray Gene expression arrays - Human endometrial stromal cells Biotin

Products Thermo Fisher Scientific GeneChip® Human Genome U133 Plus 2.0 Array

Get tips on using GeneChip® Human Genome U133 Plus 2.0 Array to perform Microarray Gene expression arrays - Rhesus monkey brain tissue Biotin

Products Thermo Fisher Scientific GeneChip® Human Genome U133 Plus 2.0 Array

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells SH-SY5Y Human neuroblastoma

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells rat nucleus pulposus

Gene silencing through the use of small interfering RNA (siRNA) has become a primary tool for identifying disease-causing genes. There are several aspects for preparing and delivering effective siRNA to knockdown a target gene. The length of siRNA should be 21–23nt long with G/C content 30–50%. If a validated siRNA sequence for your target gene is not available, use siRNA generated against the entire target gene ORF. Always work with two or three different siRNA constructs to get reliable results. If you are not sure how much siRNA to use for a given experiment, start with a transfection concentration of 10-50 nM and use siRNA-specific transfection reagent to ensure efficient siRNA delivery in a wide range of cells.

RNA siRNA / miRNA gene silencing Mouse B16 Melanoma cells FANCD2

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms