Site Directed Mutagenesis (SDM) Dog Point mutation

- Found 4525 results

Get tips on using IMAGEN™ Parainfluenza Virus Group Kit using Direct Immunofluorescence Assay to perform Cell Culture Contamination Detection Kit Virus

Products Thermo Fisher Scientific IMAGEN™ Parainfluenza Virus Group Kit using Direct Immunofluorescence Assay

Get tips on using AmpFLSTR™ Identifiler™ Direct PCR Amplification Kit to perform Cell line authentication Human iPSC cells derived from human dermal fibroblasts

Products Thermo Fisher Scientific AmpFLSTR™ Identifiler™ Direct PCR Amplification Kit

Get tips on using IMAGEN™ Respiratory Syncytial Virus Kit (RSV) using Direct Immunofluorescence Assay to perform Cell Culture Contamination Detection Kit Virus

Products Thermo Fisher Scientific IMAGEN™ Respiratory Syncytial Virus Kit (RSV) using Direct Immunofluorescence Assay

Get tips on using IMAGEN™ Influenza Virus A and B Kit using Direct Immunofluorescence Assay to perform Cell Culture Contamination Detection Kit Virus

Products Thermo Fisher Scientific IMAGEN™ Influenza Virus A and B Kit using Direct Immunofluorescence Assay

DNA-protein interactions are studied by using ChIP. The basic steps in this technique are crosslinking, sonication, immunoprecipitation, and analysis of the immunoprecipitated DNA. During ChIP, if chromatin is under-fragmented or fragments are too large which can lead to the increased background and lower resolution. Shorter cross-linking times (5-10 min) and/or lower formaldehyde concentrations (<1%) may improve shearing efficiency. If Chromatin is over-fragmented, then optimize shearing conditions for each cell type to improve ChIP efficiency. Over-sonication of chromatin may disrupt chromatin integrity and denature antibody epitopes. If you do not see any product or very little product in the input PCR reactions, add 5–10 μg chromatin per IP.

Proteins ChIP Mouse MLL-AF9/NrasG12D AML

Get tips on using Silencer® Select_FPr1/Silencer® Select_FPr2 siRNA to perform siRNA / miRNA gene silencing Mouse - Neuro 2a Fpr1/Fpr2

Products Thermo Fisher Scientific Silencer® Select_FPr1/Silencer® Select_FPr2 siRNA

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Human Adiponectin

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Human BMP-2

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Human BDNF

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Human BRCA2