Select Sample type


siRNA / RNAi /miRNA transfection Rat

- Found 5253 results

Get tips on using pSilencer 2.1-U6 Hygro to perform shRNA gene silencing Human - SHSY5Y Beclin 1

Products Thermo Fisher Scientific pSilencer 2.1-U6 Hygro

Isolating RNA from tissues and paraffin-embedded tissue samples can be challenging due to cross-linking of biomolecules and fragmented nucleic acids. The best solution is to slice the tissues into smaller pieces and make a homogenate solution (using tissue homogenizer or grinding liquid nitrogen frozen samples) in presence of RNAse inhibitors. The homogenization process should be carried out on dry ice to maintain the integrity of RNA.

RNA RNA isolation / purification Tissue Human Blood / Serum / Plasma / Buffy coat

Isolating RNA from tissues and paraffin-embedded tissue samples can be challenging due to cross-linking of biomolecules and fragmented nucleic acids. The best solution is to slice the tissues into smaller pieces and make a homogenate solution (using tissue homogenizer or grinding liquid nitrogen frozen samples) in presence of RNAse inhibitors. The homogenization process should be carried out on dry ice to maintain the integrity of RNA.

RNA RNA isolation / purification Tissue Mouse Blood / serum / plasma / buffy coat

Get tips on using pSilencer™ 4.1-CMV neo to perform shRNA gene silencing Human - SiHa AEG-1

Products Thermo Fisher Scientific pSilencer™ 4.1-CMV neo

Get tips on using pSilencer 2.1-U6 Hygro to perform shRNA gene silencing Human - Neuroblastoma cells (SH-SY5Y) Beclin 1

Products Thermo Fisher Scientific pSilencer 2.1-U6 Hygro

Get tips on using AM5770: pSilencer™ 3.1-H1 neo to perform shRNA gene silencing Mouse - CT26 OPN

Products Thermo Fisher Scientific AM5770: pSilencer™ 3.1-H1 neo

Get tips on using Target sequence1: Seq1-5'-GACTTCACGGGTGGTGTTTCT-3' to perform shRNA gene silencing Human - HEK 293T CAPN5- (Calpains) cationic lipid based

Products Custom made Target sequence1: Seq1-5'-GACTTCACGGGTGGTGTTTCT-3'

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human SH-SY5Y

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human HeLa

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human HEK293T

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms