rna-isolation-purification-cells-primary-mouse-dorsal-root-ganglion-neurons

- Found 9752 results

Get tips on using Qubit RNA HS Assay Kit to perform RNA quantification Fuorimetric - human colorectal adenocarcinoma cells (CL-187)

Products Thermo Fisher Scientific Qubit RNA HS Assay Kit

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse Ly-6A-E/Sca1

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse Ly6C/Gr-1/Ly6G

Get tips on using QIAquick Nucleotide Removal Kit (50) to perform Oligonucleotide isolation/purification

Products Qiagen QIAquick Nucleotide Removal Kit (50)

Get tips on using EZ1 ccfDNA Mini Kit (48) to perform Oligonucleotide isolation/purification

Products Qiagen EZ1 ccfDNA Mini Kit (48)

Cellular assays Purification of extracellular vesicles Exosomes Plasma

Get tips on using CelLytic™ NuCLEAR™ Extraction Kit to perform Protein isolation Tissue - Mouse cardiac tissue

Products Sigma-Aldrich CelLytic™ NuCLEAR™ Extraction Kit

The estimation of DNA methylation level heavily depends on the complete conversion of non-methylated DNA cytosines. It is crucial to ensure complete conversion of non-methylated cytosines in DNA. Therefore, it is important to incorporate controls for bisulfite reactions, as well as to pay attention to the appearance of cytosines in non-CpG sites after sequencing, which is an indicator of incomplete conversion.

DNA DNA methylation profiling Gene specific profiling Hypothalamus mouse tissue MeCP2

Get tips on using Purified Mouse Anti-p62 Ick ligand Clone 3/P62 LCK LIGAND (RUO) to perform Autophagy assay cell type - THP 1

Products BD Biosciences Purified Mouse Anti-p62 Ick ligand Clone 3/P62 LCK LIGAND (RUO)

Get tips on using Purified Mouse Anti-p62 Ick ligand Clone 3/P62 LCK LIGAND (RUO) to perform Autophagy assay cell type - SH-SY5Y

Products BD Biosciences Purified Mouse Anti-p62 Ick ligand Clone 3/P62 LCK LIGAND (RUO)

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms