I am currently using a recombinant protein which shows metal-dependent DNase activity. Is it possible to pinpoint the source of the DNase activity after protein purification? More specifically, can I ensure that the DNase activity is not because of nuclease contamination from the E.coli that might have persisted and passed with the protein of interest during purification?

Discussions Is a bacterial nuclease contamination possible during protein purification?

Cell culture media 3D Cell Culture Media hiPSC-derived retinal organoids

Get tips on using pMXs-IRES-Bsd Retroviral Expression Vector to perform CRISPR Human - Repression DDX3Y

Products Cell Biolabs pMXs-IRES-Bsd Retroviral Expression Vector

Get tips on using pMXs-IRES-Bsd Retroviral Expression Vector to perform CRISPR Human - Repression DDX3X

Products Cell Biolabs pMXs-IRES-Bsd Retroviral Expression Vector

Get tips on using Mouse Retinol Binding Protein 4 ELISA Kit (ab202404) to perform ELISA Mouse - RBP4

Products Abcam Mouse Retinol Binding Protein 4 ELISA Kit (ab202404)

Reporter gene assays are designed to test the regulation of the expression of a gene of interest. This is usually done by linking the promoter of the gene of interest with a gene such as a firefly luciferase, which can be easily detected by addition of luciferin that leads to an enzymatic reaction to produce luminescence. The enzymatic reaction can be correlated to the expression of the gene of interest. Another luciferase gene that can be used is Renilla luciferase. For an appropriate luciferase assay: 1. the reporter should express uniformly in all cells, 2. specifically respond to effectors that the assay intends to monitor, 3. have low intrinsic stability to quickly reflect transcriptional dynamics. It is important to have an equal number of cells plated in each testing condition to avoid any incorrect readouts. Reporter assays could be single or dual reporter assays. The reporter could be both luciferases. Most dual-luciferase assays involve adding two reagents to each sample and measuring luminescence following each addition. Adding the first reagent activates the first luciferase reporter reaction; adding the second reagent extinguishes first luciferase reporter activity and initiates the second luciferase reaction. Dual-luciferase assays have some advantages, including 1. reduces variability, 2. reduces background, 3. normalizes differences in transfection efficiencies between samples.

Cellular assays Reporter gene assay β-galactosidase substrates SK-Hep-1

Get tips on using Human Retinol binding protein 4 ELISA Kit (RBP4) (ab108897) to perform ELISA Human - RBP4

Products Abcam Human Retinol binding protein 4 ELISA Kit (RBP4) (ab108897)

Get tips on using Human RBP4/Retinol Binding Protein 4 PicoKine™ ELISA Kit to perform ELISA Human - RBP4

Products BosterBio Human RBP4/Retinol Binding Protein 4 PicoKine™ ELISA Kit

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human SH-SY5Y

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human HeLa