ChIP acH3 Rat Sheep BEF Tag

- Found 4688 results

Get tips on using miRNeasy Serum/Plasma Kit to perform RNA isolation / purification Tissue - Human Blood / Serum / Plasma / Buffy coat

Products Qiagen miRNeasy Serum/Plasma Kit

Get tips on using NucleoSpin® RNA Blood to perform RNA isolation / purification Tissue - Human Blood / Serum / Plasma / Buffy coat

Products Macherey Nagel NucleoSpin® RNA Blood

Get tips on using AllPrep DNA/RNA Micro Kit to perform RNA isolation / purification Tissue - Human Blood / Serum / Plasma / Buffy coat

Products Qiagen AllPrep DNA/RNA Micro Kit

Get tips on using miRNeasy Serum/Plasma Advanced Kit (50) to perform RNA isolation / purification Tissue - Livestock Blood / Serum / Plasma / Buffy coat

Products Qiagen miRNeasy Serum/Plasma Advanced Kit (50)

Get tips on using mirVana™ miRNA Isolation Kit, with phenol to perform RNA isolation / purification Tissue - Human Blood / Serum / Plasma / Buffy coat

Products Thermo Fisher Scientific mirVana™ miRNA Isolation Kit, with phenol

I intend to use iScript cDNA Synthesis Kit in order to synthesize cDNA for qPCR. I have confirmed that my RNA is pure however, according to my extraction protocol I have suspended the RNA in TE buffer containing 1mM EDTA. Will the presence of EDTA have an effect on cDNA synthesis?

Discussions Will presence of EDTA effect cDNA synthesis

Get tips on using BfaI NEB#R0568 to perform Restriction Enzymes FspBI / BfaI

Products New England BioLabs BfaI NEB#R0568

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD45

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD11b

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD34

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms