Protein expression and purification Yeast Saccharomyces cerevisiae

- Found 7427 results

Wound healing assay can be challenging due to inconsistencies and variations while making a wound on the confluent cell monolayer, consequently leads to wounds of varying sizes and widths. Moreover, this assay causes damage to the cells that are at the edge of the wound, which can prevent cell migration into the wound site and healing. The best solution is to use the standard wound healing assay kits using either combs or inserts to make a defined wound field or gap and prevent the well-to-well variation in these assays.

Cellular assays Wound healing assay cell type human gHMVEC (glioma human microvascular endothelial cells)

Get tips on using SV 96 Total RNA Isolation System to perform RNA isolation / purification Cells - primary porcine primary airway epithelial cell

Products Promega SV 96 Total RNA Isolation System

Get tips on using E.Z.N.A.® Total RNA Kit I to perform RNA isolation / purification Cells - primary bovine umbilical vein endothelial cells

Products Omega Bio Tek E.Z.N.A.® Total RNA Kit I

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells FE002-SK2 human skin progenitor cells

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells rat endothelial progenitor cells

Get tips on using GenElute™ Mammalian Total RNA Miniprep Kit to perform RNA isolation / purification Cells - primary human pancreatic stellate cells

Products Sigma-Aldrich GenElute™ Mammalian Total RNA Miniprep Kit

Get tips on using mirVana™ miRNA Isolation Kit, with phenol to perform RNA isolation / purification Cells - primary human airway epithelial cells

Products Thermo Fisher Scientific mirVana™ miRNA Isolation Kit, with phenol

Get tips on using mirVana™ miRNA Isolation Kit, with phenol to perform RNA isolation / purification Cells - primary human aortic endothelial cells

Products Thermo Fisher Scientific mirVana™ miRNA Isolation Kit, with phenol

Get tips on using TaKaRa MiniBEST Universal Genomic DNA Extraction Kit to perform DNA isolation / purification Cells - Immortalized cell lines SH-SY5Y

Products Takara Bio Inc TaKaRa MiniBEST Universal Genomic DNA Extraction Kit

Get tips on using TaKaRa MiniBEST Universal Genomic DNA Extraction Kit to perform DNA isolation / purification Cells - Immortalized cell lines HEK 293T

Products Takara Bio Inc TaKaRa MiniBEST Universal Genomic DNA Extraction Kit

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms