shRNA gene silencing Mouse Prostate cancer cell lines (DU145 and PC3) CD24

- Found 9740 results

The challenge in isolating RNA from S. aureus cells is the disruption of the cell wall. A lot of protocols employ enzymatic digestion (pretreatment) which may affect gene expression patterns of certain genes. Therefore physical disruption using beads is considered to be the better alternative.

RNA RNA isolation / purification Bacteria Gram positive Staphylococcus aureus

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD140/PDFGR2

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD14

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD34

Get tips on using LIVE/DEAD™ Fixable Blue Dead Cell Stain Kit, for UV excitation to perform Live / Dead assay mammalian cells - BHK-21

Products Thermo Fisher Scientific LIVE/DEAD™ Fixable Blue Dead Cell Stain Kit, for UV excitation

Get tips on using Live or Dead™ Cell Viability Assay Kit *Green/Red Dual Fluorescence to perform Live / Dead assay mammalian cells - rat endothelial progenitor cells

Products AAT Bioquest Live or Dead™ Cell Viability Assay Kit *Green/Red Dual Fluorescence

Get tips on using Host Cell Residual DNA contamination LANCE Ultra TR-FRET Detection Kit, 500 Assay Points to perform Cell Culture Contamination Detection Kit Bacteria

Products PerkinElmer Host Cell Residual DNA contamination LANCE Ultra TR-FRET Detection Kit, 500 Assay Points

Get tips on using CD29 antibody | 12G10 to perform Western blotting ITGB1

Products Bio-Rad Laboratories CD29 antibody | 12G10

Get tips on using Imprint® Chromatin Immunoprecipitation Kit to perform ChIP Mouse - CD4+ T

Products Sigma-Aldrich Imprint® Chromatin Immunoprecipitation Kit

Get tips on using TIANamp Genomic DNA Kit to perform DNA isolation / purification Cells - Primary cells Mouse embryonic fibroblast (MEF)

Products Tiangen TIANamp Genomic DNA Kit

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms