siRNA / miRNA gene silencing Human CRL-5915

- Found 9226 results

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD274/PD-L1

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD117/c-kit

Get tips on using pLKO5.sgRNA.EFS.GFP to perform CRISPR Mouse - Activation Neuro-2a Smn1

Products Addgene pLKO5.sgRNA.EFS.GFP

Get tips on using Hydroxymethyl Collector™ Kit to perform DNA methylation profiling Whole genome profiling - mouse primordial germ cells

Products Active Motif Hydroxymethyl Collector™ Kit

Get tips on using lenti sgRNA(MS2)_zeo backbone to perform CRISPR Mouse - Activation C2C12 FST

Products Addgene lenti sgRNA(MS2)_zeo backbone

Get tips on using Gentra Puregene Cell Kit to perform DNA isolation / purification Cells - Primary cells HUVEC

Products Qiagen Gentra Puregene Cell Kit

DNA Whole Genome Amplification Cell lines

Get tips on using Gentra Puregene Cell Kit to perform DNA isolation / purification Cells - Immortalized cell lines SH-SY5Y

Products Qiagen Gentra Puregene Cell Kit

Get tips on using Gentra Puregene Buccal Cell Kit (100) to perform DNA isolation / purification Cells - Primary cells Buccal cells

Products Qiagen Gentra Puregene Buccal Cell Kit (100)

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Rat C-Reactive Protein/CRP

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms