Get tips on using Quick Amp Labeling Kit-one color to perform RNA amplification & labeling Mammalian - RNA, Mice Cochlaea Cyanine CTP
Get tips on using AllPrep Bacterial DNA/RNA/Protein Kit (50) to perform DNA isolation / purification Bacteria - Gram negative Massilia sp
Get tips on using MasterPure™ Complete DNA and RNA Purification Kit to perform DNA isolation / purification Cells - Immortalized cell lines C2C12
Get tips on using GeneChip® HT 3' IVT PLUS Reagent Kit to perform RNA amplification & labeling Mammalian - RNA, Human Endometrial Stromal cells Biotin
Get tips on using Amino Allyl MessageAmp™ II aRNA Amplification Kit to perform RNA amplification & labeling Fish - Total RNA, Fundulus heteroclitus Cyanine 3 & 5
Get tips on using GeneChip® Human Genome U133 Plus 2.0 Array to perform RNA amplification & labeling Mammalian - RNA amplification and Labeling Human Endometrial Stromal cells Biotin
Get tips on using GeneChip® Human Genome U133 Plus 2.0 Array to perform RNA amplification & labeling Mammalian - RNA, rhesus monkey brain tissue Human endothelail stromal cells
I have extracted RNA from brain tissue but my RNA concentrations are as low as 5ng/ml with my highest being around 80ng/ml. Will I be able to perform cDNA conversion with concentrations as low as these?
Cell cytotoxicity assays measure the ability of certain compounds or chemical mediators to reduce the viability of the cells. The term cell cytotoxicity assay can sometimes be used interchangeably with cell proliferation assay. Healthy living cells can be identified by the use of formazan dyes, protease biomarkers or by measuring ATP content. The formazan dyes are chromogenic products formed by the reduction of tetrazolium salts by dehydrogenases, such as lactate dehydrogenase (LDH) and reductases that are released during cell death. Common tetrazolium salts include INT, MTT, MTS and XTT. Cell cytotoxicity can also be measured by using the SRB and WST-1 assays. These assays can usually be used in a high-throughput fashion and can be quantitated by measuring absorbance, colorimetry or luminescence. All these assays require similar numbers of cell plating at the initiation, a time course of treatment with the cytotoxic agent and at least triplicates for each condition at every point of analysis. Cell shrinkage, plasma membrane blebbing, cell detachment, externalization of phosphatidylserine, nuclear condensation and ultimately DNA fragmentation are well-described features of apoptosis. The assays that rely on cell membrane integrity for their function, may not be able to quantify early apoptosis. Therefore, in order to distinguish early apoptotic vs. late apoptotic or necrotic cells, additional flow cytometry techniques can be used. A combination of Annexin V and PI (propidium iodide) can be used to distinguish early (Annexin V+/PI-) and late apoptotic (Annexin V+/PI+) cells. Sometimes, caspase assays are used in order to differentiate the stages of apoptosis.
Cell cytotoxicity assays measure the ability of certain compounds or chemical mediators to reduce the viability of the cells. The term cell cytotoxicity assay can sometimes be used interchangeably with cell proliferation assay. Healthy living cells can be identified by the use of formazan dyes, protease biomarkers or by measuring ATP content. The formazan dyes are chromogenic products formed by the reduction of tetrazolium salts by dehydrogenases, such as lactate dehydrogenase (LDH) and reductases that are released during cell death. Common tetrazolium salts include INT, MTT, MTS and XTT. Cell cytotoxicity can also be measured by using the SRB and WST-1 assays. These assays can usually be used in a high-throughput fashion and can be quantitated by measuring absorbance, colorimetry or luminescence. All these assays require similar numbers of cell plating at the initiation, a time course of treatment with the cytotoxic agent and at least triplicates for each condition at every point of analysis. Cell shrinkage, plasma membrane blebbing, cell detachment, externalization of phosphatidylserine, nuclear condensation and ultimately DNA fragmentation are well-described features of apoptosis. The assays that rely on cell membrane integrity for their function, may not be able to quantify early apoptosis. Therefore, in order to distinguish early apoptotic vs. late apoptotic or necrotic cells, additional flow cytometry techniques can be used. A combination of Annexin V and PI (propidium iodide) can be used to distinguish early (Annexin V+/PI-) and late apoptotic (Annexin V+/PI+) cells. Sometimes, caspase assays are used in order to differentiate the stages of apoptosis.
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment