rna-isolation-purification-tissue-rat-spinal-cord

- Found 6691 results

Get tips on using Corning® 500 mL SF Medium, [+] L-glutamine and 1 g/L BSA to perform Stem cell culture media Ovarian cancer stem cells (Caov3, 3AO, SKOV3)

Products Corning Corning® 500 mL SF Medium, [+] L-glutamine and 1 g/L BSA

Get tips on using Corning™ Basal Cell Culture Liquid Media - DMEM and Ham's F-12, 50/50 Mix to perform Mammalian cell culture media HSG cells

Products Fisher Scientific Corning™ Basal Cell Culture Liquid Media - DMEM and Ham's F-12, 50/50 Mix

RNA siRNA / miRNA gene silencing Mouse siRNA negative control polymer / lipid

Get tips on using Corning® BioCoat™ Matrigel® Invasion Chamber with 8.0 µm PET Membrane in four 6-well Plates to perform Cell migration / Invasion cell type - 4T1

Products Corning Corning® BioCoat™ Matrigel® Invasion Chamber with 8.0 µm PET Membrane in four 6-well Plates

Get tips on using Corning® BioCoat™ Matrigel® Invasion Chambers with 8.0 µm PET Membrane in two 24-well Plates to perform Cell migration / Invasion cell type - BxPC-3

Products Corning Corning® BioCoat™ Matrigel® Invasion Chambers with 8.0 µm PET Membrane in two 24-well Plates

Get tips on using Corning® BioCoat™ Matrigel® Invasion Chambers with 8.0 µm PET Membrane in two 24-well Plates to perform Cell migration / Invasion cell type - MG-63

Products Corning Corning® BioCoat™ Matrigel® Invasion Chambers with 8.0 µm PET Membrane in two 24-well Plates

The most widely used method for protein quantification is by spectrophotometry. The concentration of the protein in the samples is measured at an absorbance of 280 nm. The absorbance of the sample protein is then plotted against a standard curve. This method allows for total protein quantification in a sample (cell and tissue extracts). Before analysing the concentration of protein in the sample, it is important to choose the right test method.  For high protein concentration samples (above 5 - 160 mg/ml) the best method is to use the Biuret test. For low concentrations samples (between 1 - 2000µg/ml) the best methods are Lowry assay, BCA assay, Bradford assay and coomassie blue (for exact sensitivity of the test kits you use, refer to manufacturer's protocol). If the samples contain detergents like Triton X-100 then BCA assay is the best choice. For samples that have proteins larger than 3 KDa in size Bradford assay is the best choice. Each method has advantages and disadvantages, plan your analysis considering your sample characteristics.

Proteins Protein quantification Colorimetric method

The most widely used method for protein quantification is by spectrophotometry. The concentration of the protein in the samples is measured at an absorbance of 280 nm. The absorbance of the sample protein is then plotted against a standard curve. This method allows for total protein quantification in a sample (cell and tissue extracts). Before analysing the concentration of protein in the sample, it is important to choose the right test method.  For high protein concentration samples (above 5 - 160 mg/ml) the best method is to use the Biuret test. For low concentrations samples (between 1 - 2000µg/ml) the best methods are Lowry assay, BCA assay, Bradford assay and coomassie blue (for exact sensitivity of the test kits you use, refer to manufacturer's protocol). If the samples contain detergents like Triton X-100 then BCA assay is the best choice. For samples that have proteins larger than 3 KDa in size Bradford assay is the best choice. Each method has advantages and disadvantages, plan your analysis considering your sample characteristics.

Proteins Protein quantification Fluorimetric method

As autophagy is a multi-step process which includes not just the formation of autophagosomes, but most importantly, flux through the entire system, including the degradation upon fusion with lysosomes, which makes it quite challenging for detection. There are several methods for detection in mammalian cells, including immunoblotting analysis of LC3 and p62 and detection of autophagosome formation/maturation by fluorescence microscopy, Currently, there is no single “gold standard” for determining the autophagic activity that is applicable in every experimental context, hence it is recommended to go for the combined use of multiple methods to accurately assess the autophagic activity in any given biological setting.

Cellular assays Autophagy assay cell type RAW 264.7

As autophagy is a multi-step process which includes not just the formation of autophagosomes, but most importantly, flux through the entire system, including the degradation upon fusion with lysosomes, which makes it quite challenging for detection. There are several methods for detection in mammalian cells, including immunoblotting analysis of LC3 and p62 and detection of autophagosome formation/maturation by fluorescence microscopy, Currently, there is no single “gold standard” for determining the autophagic activity that is applicable in every experimental context, hence it is recommended to go for the combined use of multiple methods to accurately assess the autophagic activity in any given biological setting.

Cellular assays Autophagy assay cell type Ramos

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms