Get tips on using SimpleChIP® Enzymatic Chromatin IP Kit (Magnetic Beads) #9003 to perform ChIP Mouse - 3T3-L1 cells
Get tips on using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Magnetic Beads) #9005 to perform ChIP Rat - Mesenteric arteries
Get tips on using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Agarose Beads) #9004 to perform ChIP Human - PANC-1
Get tips on using Human Chitinase 3-like 1 DuoSet ELISA to perform ELISA Human - Chitinase-3-Like Protein-1 (CHI3L1) or YKL-40
Get tips on using Mouse Chitinase 3-like 1 Quantikine ELISA Kit to perform ELISA Mouse - Chitinase-3-Like Protein-1 (CHI3L1) or YKL-40
Get tips on using Human Chitinase 3-like 1/YKL-40 PicoKine™ ELISA Kit EK0974 to perform ELISA Human - Chitinase-3-Like Protein-1 (CHI3L1) or YKL-40
Get tips on using pET20b-chIL-7/H to perform Protein Expression Prokaryotic cells - E. coli chicken IL-7
ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.
ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.
Get tips on using MicroVue YKL-40 EIA to perform ELISA Human - Chitinase-3-Like Protein-1 (CHI3L1) or YKL-40
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment