Select a Cell type


DNA quantification Mouse

- Found 4558 results

Isolating DNA from tissues and paraffin-embedded tissue samples can be challenging as double-stranded DNA is physically fragile and highly susceptible to exo- and endonucleases. The best solution is to slice the tissues into smaller pieces and make a homogenate solution (using tissue homogenizer or grinding liquid nitrogen frozen samples) in the presence of DNAse inhibitors. Further, extracting DNA from the nucleus need specific methods by combining physical, mechanical and chemical lysis approaches,

DNA DNA isolation / purification Cells Immortalized cell lines 3T3

Isolating DNA from tissues and paraffin-embedded tissue samples can be challenging as double-stranded DNA is physically fragile and highly susceptible to exo- and endonucleases. The best solution is to slice the tissues into smaller pieces and make a homogenate solution (using tissue homogenizer or grinding liquid nitrogen frozen samples) in the presence of DNAse inhibitors. Further, extracting DNA from the nucleus need specific methods by combining physical, mechanical and chemical lysis approaches,

DNA DNA isolation / purification Cells Immortalized cell lines C2C12

Get tips on using EpiCult™-B Mouse Medium Kit to perform 3D Cell Culture Media Mouse primary breast ephitelial cells-Mammospheres

Products STEMCELL technologies EpiCult™-B Mouse Medium Kit

Get tips on using Whole Mouse Genome Microarray Kit, 4x44K to perform Microarray Gene expression arrays - Mouse liver tissue Cyanine-3-CTP

Products Agilent Technologies Whole Mouse Genome Microarray Kit, 4x44K

Get tips on using DreamTaq DNA Polymerases to perform PCR Conventional / Qualitative PCR - bacterial DNA

Products Thermo Fisher Scientific DreamTaq DNA Polymerases

Get tips on using Biotools DNA Polymerase to perform PCR Conventional / Qualitative PCR - bacterial DNA

Products Biotools Biotools DNA Polymerase

Microarrays enable researchers to monitor the expression of thousands of genes simultaneously. However, the sensitivity, accuracy, specificity, and reproducibility are major challenges for this technology. Cross-hybridization, combination with splice variants, is a prime source for the discrepancies in differential gene expression calls among various microarray platforms. Removing (either from production or downstream bioinformatic analysis) and/or redesigning the microarray probes prone to cross-hybridization is a reasonable strategy to increase the hybridization specificity and hence, the accuracy of the microarray measurements.

DNA Microarray RNA amplification & Labeling Mouse brain tissue Biotin

Microarrays enable researchers to monitor the expression of thousands of genes simultaneously. However, the sensitivity, accuracy, specificity, and reproducibility are major challenges for this technology. Cross-hybridization, combination with splice variants, is a prime source for the discrepancies in differential gene expression calls among various microarray platforms. Removing (either from production or downstream bioinformatic analysis) and/or redesigning the microarray probes prone to cross-hybridization is a reasonable strategy to increase the hybridization specificity and hence, the accuracy of the microarray measurements.

DNA Microarray RNA amplification & Labeling Mouse mammary tissue Biotin

Microarrays enable researchers to monitor the expression of thousands of genes simultaneously. However, the sensitivity, accuracy, specificity, and reproducibility are major challenges for this technology. Cross-hybridization, combination with splice variants, is a prime source for the discrepancies in differential gene expression calls among various microarray platforms. Removing (either from production or downstream bioinformatic analysis) and/or redesigning the microarray probes prone to cross-hybridization is a reasonable strategy to increase the hybridization specificity and hence, the accuracy of the microarray measurements.

DNA Microarray RNA amplification & Labeling Mouse skin tissue Biotin

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Mouse Neuroblastoma 2a Epac1

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms