Cell Culture Contamination Detection Kit

- Found 8489 results

Get tips on using Corning® BioCoat™ Tumor Invasion 24-well Plate to perform Cell migration / Invasion cell type - SaOS-2

Products Corning Corning® BioCoat™ Tumor Invasion 24-well Plate

Protein ladders are a set of standards known as molecular weight proteins that are utilized to identify the approximate size of a protein molecule run on a PAGE gel electrophoresis. The challenges in running the ladders are the choice of appropriate protein standard as it is used as visual evidence of protein migration, transfer efficiency, and positive control. Suitable protein markers can be selected on the basis of required properties and applications, i.e., fluorescent ladder, IEF, 2D SDS-PAGE ladder, natural ladder with an isoelectric point, and optimized ladders for Western Blot chemiluminescence detection. The key factors for running a distinct protein ladder are buffer conditions, charge/voltage at migration time, and the gel's concentration.

Proteins Protein Ladder IEF and 2-D Standards

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Human KIM-1

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Rat KIM-1

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Mouse KIM-1

Get tips on using CytoTox 96® Non-Radioactive Cytotoxicity Assay to perform Cell cytotoxicity / Proliferation assay cell type - BxPc-3 human primary pancreatic adenocarcinoma

Products Promega CytoTox 96® Non-Radioactive Cytotoxicity Assay

Get tips on using ChIP-IT® Express Chromatin Immunoprecipitation Kits to perform ChIP Human - Fibroblast cell lines

Products Active Motif ChIP-IT® Express Chromatin Immunoprecipitation Kits

A standard angiogenic assay involves the autonomous endothelial cell response of self-organization into microvessels, also known as tubes when seeded on a basement membrane matrix in the presence of the appropriate growth factors. However, the component of basement membrane matrix may also affect the tube formation by endothelial cells. Hence it is important to use a standard angiogenesis assay kit or use the same membrane matrix with known composition to standardize the assay conditions.

Cellular assays Angiogenesis assay human bone marrow mononuclear cells

A standard angiogenic assay involves the autonomous endothelial cell response of self-organization into microvessels, also known as tubes when seeded on a basement membrane matrix in the presence of the appropriate growth factors. However, the component of basement membrane matrix may also affect the tube formation by endothelial cells. Hence it is important to use a standard angiogenesis assay kit or use the same membrane matrix with known composition to standardize the assay conditions.

Cellular assays Angiogenesis assay human HUVEC

A standard angiogenic assay involves the autonomous endothelial cell response of self-organization into microvessels, also known as tubes when seeded on a basement membrane matrix in the presence of the appropriate growth factors. However, the component of basement membrane matrix may also affect the tube formation by endothelial cells. Hence it is important to use a standard angiogenesis assay kit or use the same membrane matrix with known composition to standardize the assay conditions.

Cellular assays Angiogenesis assay human HMVEC

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms