Get tips on using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Magnetic Beads) #9005 to perform ChIP Rat - Pancreas
Get tips on using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Magnetic Beads) #9005 to perform ChIP Mouse - Brain
Get tips on using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Agarose Beads) #9004 to perform ChIP Mouse - Panc02
Get tips on using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Agarose Beads) #9004 to perform ChIP Mouse - BMDCs
Get tips on using Ambion™ RecoverAll™ Total Nucleic Acid Isolation Kit for FFPE to perform RNA isolation / purification Tissue - rat kidney tissue
Get tips on using SimpleChIP® Plus Enzymatic Chromatin IP Kit (Magnetic Beads) #9005 to perform ChIP Rat - Mesenteric arteries
Get tips on using Pre-designed and validated siRNA against gene IGFBP1 to perform siRNA / miRNA gene silencing Human - Primary Endometrial Stromal Cells IGFBP1 (Insuline-like growth factor binding protein-1)
Get tips on using SurePrint G3 Mouse Exon 4x180K Microarray Kit (165,984 Exon probes) to perform Microarray Mice - Cochlea Expression array (labelled)
Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
Get tips on using SurePrint G3 Mouse Exon 4x180K Microarray Kit (165,984 Exon probes) to perform Microarray Gene expression arrays - Mouse Cyanine-CTP
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment