Protein expression and purification Insect cells S2

- Found 9457 results

DNA ladder is typically used as a reference to estimate the size of unknown DNA samples that are separated based on their mobility in an electrical field. The critical points for running a DNA ladder are compatibility with running buffer, agarose gel percentage, and choosing the correct range of DNA ladder for sizing DNA molecules.

DNA DNA Ladder 20 bp

DNA ladder is typically used as a reference to estimate the size of unknown DNA samples that are separated based on their mobility in an electrical field. The critical points for running a DNA ladder are compatibility with running buffer, agarose gel percentage, and choosing the correct range of DNA ladder for sizing DNA molecules.

DNA DNA Ladder Medium Range

DNA ladder is typically used as a reference to estimate the size of unknown DNA samples that are separated based on their mobility in an electrical field. The critical points for running a DNA ladder are compatibility with running buffer, agarose gel percentage, and choosing the correct range of DNA ladder for sizing DNA molecules.

DNA DNA Ladder 10 bp

DNA ladder is typically used as a reference to estimate the size of unknown DNA samples that are separated based on their mobility in an electrical field. The critical points for running a DNA ladder are compatibility with running buffer, agarose gel percentage, and choosing the correct range of DNA ladder for sizing DNA molecules.

DNA DNA Ladder 25 bp

DNA ladder is typically used as a reference to estimate the size of unknown DNA samples that are separated based on their mobility in an electrical field. The critical points for running a DNA ladder are compatibility with running buffer, agarose gel percentage, and choosing the correct range of DNA ladder for sizing DNA molecules.

DNA DNA Ladder Low Range

Get tips on using LIVE/DEAD™ Fixable Near-IR Dead Cell Stain Kit, for 633 or 635 nm excitation to perform Live / Dead assay mammalian cells - rat testicular tissue

Products Thermo Fisher Scientific LIVE/DEAD™ Fixable Near-IR Dead Cell Stain Kit, for 633 or 635 nm excitation

I used a serum/plasma kit for my serum samples. After the phase separation the samples should have 3 phases: a colourless aqueous phase, a white interphase and a red organic phase. However, in some of my samples there was no aqueous phase unless I wait for an extended period of time. How can I circumvent this problem?

Discussions Problem in phase separation after using serum/plasma kit

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Human Point mutation LNCaP Androgen Receptor splice variant (AR-V)

Get tips on using QIAGEN Protease (30 AU) to perform Digestion during DNA preparation

Products Qiagen QIAGEN Protease (30 AU)

Cellular assays Cell Isolation Hematopoietic Progenitor Cell

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms