Site Directed Mutagenesis (SDM) Human Point mutation PC-3

- Found 6654 results

Get tips on using ROS-ID® Total ROS/Superoxide detection kit to perform ROS assay cell type - PANC-, BxPC-3 human pancreas

Products Enzo Life Sciences ROS-ID® Total ROS/Superoxide detection kit

Get tips on using Amino Allyl MessageAmp™ II aRNA Amplification Kit to perform Microarray RNA amplification & Labeling - Human brain tissue Cyanine 3

Products Thermo Fisher Scientific Amino Allyl MessageAmp™ II aRNA Amplification Kit

Get tips on using siGENOME Human GSK3A (2931) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Human - PANC-1 GSK-3α

Products Horizon Discovery Ltd. siGENOME Human GSK3A (2931) siRNA - SMARTpool

TUNEL assay is the cell death detection method where the biochemical marker of apoptosis is DNA fragmentation. The assay involves the microscopical detection of generated DNA fragments with free 3'-hydroxyl residues. in apoptotic cells using enzyme terminal deoxynucleotidyl transferase (TdT) which adds biotinylated nucleotides at the site of DNA breaks. Major challenges of this method involve proper access of the enzyme which could be hampered by poor permeabilization and/or excessive fixation with cross-linking fixative (common with archival tissue). This issue can be resolved by optimizing the incubation time with Proteinase K or CytoninTM.

Cellular assays TUNEL assay cell type HNSCC Detroit 562 human head and neck tumor cells

miRNA is the inherent gene silencing machinery which can have more than one mRNA target, whereas siRNA can be designed to target a particular mRNA target. By design, both siRNA and miRNA are 20-25 nucleotides in length. The target sequence for siRNAs is usually located within the open reading frame, between 50 and 100 nucleotides downstream of the start codon. There are two ways in which cells can be transfected with desired RNAi: 1. Direct transfection (with calcium phosphate co-precipitation or cationic lipid mediated transfection using lipofectamine or oligofectamine), and 2. Making RNAi lentiviral constructs (followed by transformation and transduction). Lentiviral constructs are time consuming, but provide a more permanent expression of RNAi in the cells, and consistent gene silencing. Direct transfection of oligonucleotides provides temporary genetic suppression. Traditional methods like calcium phosphate co-precipitation have challenges like low efficiency, poor reproducibility and cell toxicity. Whereas, cationic lipid-based transfection reagents are able to overcome these challenges, along with applicability to a large variety of eukaryotic cell lines. When using oligos, the ideal concentration lies between 10-50nM for effective transfection.

RNA siRNA / miRNA gene silencing Human Primary Human Hepatocytes CYP3A4

miRNA is the inherent gene silencing machinery which can have more than one mRNA target, whereas siRNA can be designed to target a particular mRNA target. By design, both siRNA and miRNA are 20-25 nucleotides in length. The target sequence for siRNAs is usually located within the open reading frame, between 50 and 100 nucleotides downstream of the start codon. There are two ways in which cells can be transfected with desired RNAi: 1. Direct transfection (with calcium phosphate co-precipitation or cationic lipid mediated transfection using lipofectamine or oligofectamine), and 2. Making RNAi lentiviral constructs (followed by transformation and transduction). Lentiviral constructs are time consuming, but provide a more permanent expression of RNAi in the cells, and consistent gene silencing. Direct transfection of oligonucleotides provides temporary genetic suppression. Traditional methods like calcium phosphate co-precipitation have challenges like low efficiency, poor reproducibility and cell toxicity. Whereas, cationic lipid-based transfection reagents are able to overcome these challenges, along with applicability to a large variety of eukaryotic cell lines. When using oligos, the ideal concentration lies between 10-50nM for effective transfection.

RNA siRNA / miRNA gene silencing Human Primary Human Hepatocytes CYP2B6

Wound healing assay can be challenging due to inconsistencies and variations while making a wound on the confluent cell monolayer, consequently leads to wounds of varying sizes and widths. Moreover, this assay causes damage to the cells that are at the edge of the wound, which can prevent cell migration into the wound site and healing. The best solution is to use the standard wound healing assay kits using either combs or inserts to make a defined wound field or gap and prevent the well-to-well variation in these assays.

Cellular assays Wound healing assay cell type human HUVEC

Wound healing assay can be challenging due to inconsistencies and variations while making a wound on the confluent cell monolayer, consequently leads to wounds of varying sizes and widths. Moreover, this assay causes damage to the cells that are at the edge of the wound, which can prevent cell migration into the wound site and healing. The best solution is to use the standard wound healing assay kits using either combs or inserts to make a defined wound field or gap and prevent the well-to-well variation in these assays.

Cellular assays Wound healing assay cell type human HMEC

Wound healing assay can be challenging due to inconsistencies and variations while making a wound on the confluent cell monolayer, consequently leads to wounds of varying sizes and widths. Moreover, this assay causes damage to the cells that are at the edge of the wound, which can prevent cell migration into the wound site and healing. The best solution is to use the standard wound healing assay kits using either combs or inserts to make a defined wound field or gap and prevent the well-to-well variation in these assays.

Cellular assays Wound healing assay cell type human A549

Wound healing assay can be challenging due to inconsistencies and variations while making a wound on the confluent cell monolayer, consequently leads to wounds of varying sizes and widths. Moreover, this assay causes damage to the cells that are at the edge of the wound, which can prevent cell migration into the wound site and healing. The best solution is to use the standard wound healing assay kits using either combs or inserts to make a defined wound field or gap and prevent the well-to-well variation in these assays.

Cellular assays Wound healing assay cell type human BEAS2B

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms