siRNA / miRNA gene silencing Rat MTLn3 (rat mammary adenocarcinoma breast cancer cell line)

- Found 8613 results

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD110/Thrombopoietin R

Get tips on using EpiQuik Dnmt3A Assay Kit to perform DNA methylation profiling Whole genome profiling - human peripheral blood mononuclear cells

Products Epigentek EpiQuik Dnmt3A Assay Kit

Get tips on using SurePrint G3 Human CGH Microarray Kit, 4x180K to perform Microarray Comperative genomic hybridization - Human Blood cells

Products Agilent Technologies SurePrint G3 Human CGH Microarray Kit, 4x180K

Get tips on using SurePrint G3 Human CGH Microarray Kit, 2x400K to perform Microarray Comperative genomic hybridization - Human Blood cells

Products Agilent Technologies SurePrint G3 Human CGH Microarray Kit, 2x400K

Get tips on using Imprint® Methylated DNA Quantification Kit to perform DNA methylation profiling Whole genome profiling - C2C12 mouse myoblast cells

Products Sigma-Aldrich Imprint® Methylated DNA Quantification Kit

Get tips on using MethylFlash Methylated DNA 5-mC Quantification Kit to perform DNA methylation profiling Whole genome profiling - C2C12 mouse myoblast cells

Products Epigentek MethylFlash Methylated DNA 5-mC Quantification Kit

Hello everyone! I am going to do a live/dead assay for my cells and I saw that I can use both fluorescence and absorbance as my detection method. Is there a difference in the results depending on the method? Is one method preferred over the other in certain situations?

Discussions Live/dead assay Bacteria

DNA isolation and purification is the first critical step in sample preparation that helps ensure optimal performance of downstream assays like PCR, microarrays, and sequencing. Failure in yielding high-quality DNA would be the major reason that DNA doesn't work for the downstream application. To circumvent this, one should follow the recommended storage conditions to minimize DNA degradation by nucleases and shouldn't overload the purification system.

DNA DNA isolation / purification Cells Primary cells Mouse embryonic fibroblast (MEF)

Get tips on using Lysozyme EC 3.2.1.17 (Concentrate) to perform Immunohistochemistry Mouse - Lysozyme

Products Agilent Technologies Lysozyme EC 3.2.1.17 (Concentrate)

Get tips on using Monoclonal Mouse Anti-Bromodeoxyuridine (Concentrate) Clone Bu20a to perform Immunohistochemistry Mouse - BrdU

Products Agilent Technologies Monoclonal Mouse Anti-Bromodeoxyuridine (Concentrate) Clone Bu20a

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms