CRISPR Mouse Deletion B117P

- Found 2963 results

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD274/PD-L1

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD117/c-kit

Get tips on using PE-Cy™7 Rat anti-Mouse CD117 to perform Flow cytometry Anti-bodies Mouse - CD117/c-kit

Products BD Biosciences PE-Cy™7 Rat anti-Mouse CD117

Get tips on using PE-Cy™7 Rat Anti-Mouse CD31 to perform Flow cytometry Anti-bodies Mouse - CD31/Pecam-1

Products BD Biosciences PE-Cy™7 Rat Anti-Mouse CD31

Get tips on using ON-TARGET plus Mouse Becn1 (56208) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Mouse - 4T1 BECN-1

Products Horizon Discovery Ltd. ON-TARGET plus Mouse Becn1 (56208) siRNA - SMARTpool

Get tips on using Immun-Star Goat Anti-Mouse (GAM)-HRP Conjugate to perform Western blot Secondary Antibody - Goat Mouse Horseradish peroxidase

Products Bio-Rad Laboratories Immun-Star Goat Anti-Mouse (GAM)-HRP Conjugate

A standard angiogenic assay involves the autonomous endothelial cell response of self-organization into microvessels, also known as tubes when seeded on a basement membrane matrix in the presence of the appropriate growth factors. However, the component of basement membrane matrix may also affect the tube formation by endothelial cells. Hence it is important to use a standard angiogenesis assay kit or use the same membrane matrix with known composition to standardize the assay conditions.

Cellular assays Angiogenesis assay mouse MS1

Get tips on using FITC Mouse Anti-Human CD51/CD61 to perform Flow cytometry Anti-bodies Human - CD51

Products BD Biosciences FITC Mouse Anti-Human CD51/CD61

Get tips on using PE Mouse Anti-Human CD51/CD61 to perform Flow cytometry Anti-bodies Human - CD51

Products BD Biosciences PE Mouse Anti-Human CD51/CD61

Get tips on using APC-H7 Mouse Anti-Human CD43 to perform Flow cytometry Anti-bodies Human - CD43

Products BD Biosciences APC-H7 Mouse Anti-Human CD43

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms