siRNA / miRNA gene silencing Human ES2(ovarian cancer cell line)

- Found 9020 results

Isolating RNA from tissues and paraffin-embedded tissue samples can be challenging due to cross-linking of biomolecules and fragmented nucleic acids. The best solution is to slice the tissues into smaller pieces and make a homogenate solution (using tissue homogenizer or grinding liquid nitrogen frozen samples) in presence of RNAse inhibitors. The homogenization process should be carried out on dry ice to maintain the integrity of RNA

RNA RNA isolation / purification Tissue Rat Blood / Serum / Plasma / Buffy coat

Get tips on using pX330-U6-Chimeric_BB-CBh-hSpCas9 to perform CRISPR Mouse - Deletion ES (embryonic stem) cells Slx2

Products Addgene pX330-U6-Chimeric_BB-CBh-hSpCas9

Get tips on using pSpCas9(BB)-2A-GFP (PX458) to perform CRISPR Mouse - Deletion ES (embryonic stem) cells MIR

Products Addgene pSpCas9(BB)-2A-GFP (PX458)

Get tips on using pSpCas9(BB)-2A-Puro (PX459) to perform CRISPR Mouse - Deletion ES (embryonic stem) cells Etv2 promoter

Products Addgene pSpCas9(BB)-2A-Puro (PX459)

Hello! I used Trizol to extract total RNA from in-vitro cultured bacteria (1 X 10^8 cells). After phase separation, I mixed ~0.4 ml of the upper phase which contains RNA with 0.5 mL cold isopropanol. However, the amount of RNA when measured in Nanodrop was very low. In addition, the ratio between 260 and 230 was around 0.1 to 0.5. Is there a chance that my sample was contaminated by the Trizol reagent? When I collected the aqueous phase I made sure to not touch the lower phase. What should I do?

Discussions Some help with RNA isolation using Trizol

The DNA concentration after using this DNA isolation kit is sometimes too low and thus it is not sufficient for my follow-up experiments. How can I improve it?

Discussions How can I improve my DNA yield?

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Mouse BV-2

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Mouse RAW264.7

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Mouse J774

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Mouse NSC-34

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms