FACS CD14

- Found 986 results

Gene silencing through the use of small interfering RNA (siRNA) has become a primary tool for identifying disease-causing genes. There are several aspects for preparing and delivering effective siRNA to knockdown a target gene. The length of siRNA should be 21–23nt long with G/C content 30–50%. If a validated siRNA sequence for your target gene is not available, use siRNA generated against the entire target gene ORF. Always work with two or three different siRNA constructs to get reliable results. If you are not sure how much siRNA to use for a given experiment, start with a transfection concentration of 10-50 nM and use siRNA-specific transfection reagent to ensure efficient siRNA delivery in a wide range of cells.

RNA siRNA / miRNA gene silencing Human HaCaT CD44

Get tips on using ALCAM Antibody (B-6): sc-74558 to perform Immunohistochemistry Mouse - CD166 / ALCAM

Products Santa Cruz Biotechnology ALCAM Antibody (B-6): sc-74558

Get tips on using Nectin 1 Monoclonal Antibody (CK8) to perform Flow cytometry Anti-bodies Human - CD111/Nectin-1

Products eBioscience Nectin 1 Monoclonal Antibody (CK8)

Get tips on using Human IL-6R alpha Antibody to perform Flow cytometry Anti-bodies Human - CD126/IL-6Ralpha

Products R&D Systems Human IL-6R alpha Antibody

Get tips on using Anti-Human L1CAM Therapeutic Antibody Fab Fragment to perform Flow cytometry Anti-bodies Human - CD171/L1CAM

Products Creative BioLabs Anti-Human L1CAM Therapeutic Antibody Fab Fragment

Western blotting is a widely used technique to size separate proteins from a pool of cell or tissue lysates. The technique has 4 major steps: a) gel electrophoresis, b) blocking and treatment with antigen specific antibody, c) treatment with secondary antibody and finally d) detection and visualization. Though western blotting is a widely used technique, detection of specific proteins depends on several factors, the major ones are antibody concentration, incubation time and washing steps. Key points for obtaining clean blots are: always prepare fresh buffer solutions and optimize antibody concentration. Given the advent of high-throughput protein analysis and a push to limit the use of lab consumables, onestep antibodies are developed which recognise protein of interest and also contain a detection label.

Proteins Western blotting Fas

Get tips on using Human Thrombopoietin R/Tpo R APC-conjugated Antibody to perform Flow cytometry Anti-bodies Human - CD110/Thrombopoietin R

Products R&D Systems Human Thrombopoietin R/Tpo R APC-conjugated Antibody

Get tips on using Human Thrombopoietin R/Tpo R PE-conjugated Antibody to perform Flow cytometry Anti-bodies Human - CD110/Thrombopoietin R

Products R&D Systems Human Thrombopoietin R/Tpo R PE-conjugated Antibody

Get tips on using QuikChange Site-Directed Mutagenesis Kit, 10 Rxn to perform Site Directed Mutagenesis (SDM) Human - Point mutation MDA-MB-231 CD44

Products Agilent Technologies QuikChange Site-Directed Mutagenesis Kit, 10 Rxn

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD11b

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms