siRNA / miRNA gene silencing Human OVCAR-3

- Found 5760 results

Get tips on using ROS-ID® Total ROS/Superoxide detection kit to perform ROS assay cell type - PANC-, BxPC-3 human pancreas

Products Enzo Life Sciences ROS-ID® Total ROS/Superoxide detection kit

Get tips on using OxiSelect™ Intracellular ROS Assay Kit (Green Fluorescence) to perform ROS assay cell type - PC-3 human prostate adenocarcinoma

Products Cell Biolabs OxiSelect™ Intracellular ROS Assay Kit (Green Fluorescence)

Get tips on using ROS-ID® Total ROS/Superoxide detection kit to perform ROS assay cell type - PC-3 human prostate adenocarcinoma

Products Enzo Life Sciences ROS-ID® Total ROS/Superoxide detection kit

Get tips on using Amino Allyl MessageAmp™ II aRNA Amplification Kit to perform Microarray RNA amplification & Labeling - Human brain tissue Cyanine 3

Products Thermo Fisher Scientific Amino Allyl MessageAmp™ II aRNA Amplification Kit

The estimation of DNA methylation level heavily depends on the complete conversion of non-methylated DNA cytosines. It is crucial to ensure complete conversion of non-methylated cytosines in DNA. Therefore, it is important to incorporate controls for bisulfite reactions, as well as to pay attention to the appearance of cytosines in non-CpG sites after sequencing, which is an indicator of incomplete conversion.

DNA DNA methylation profiling Gene specific profiling A2780 miR-30c-5p

The estimation of DNA methylation level heavily depends on the complete conversion of non-methylated DNA cytosines. It is crucial to ensure complete conversion of non-methylated cytosines in DNA. Therefore, it is important to incorporate controls for bisulfite reactions, as well as to pay attention to the appearance of cytosines in non-CpG sites after sequencing, which is an indicator of incomplete conversion.

DNA DNA methylation profiling Gene specific profiling A2780 miR-30a-5p

The estimation of DNA methylation level heavily depends on the complete conversion of non-methylated DNA cytosines. It is crucial to ensure complete conversion of non-methylated cytosines in DNA. Therefore, it is important to incorporate controls for bisulfite reactions, as well as to pay attention to the appearance of cytosines in non-CpG sites after sequencing, which is an indicator of incomplete conversion.

DNA DNA methylation profiling Gene specific profiling MG-63 miR-34a

Get tips on using Gal-Screen™ β-Galactosidase Reporter Gene Assay System for Mammalian Cells to perform Reporter gene assay β-galactosidase substrates - yeast, Yarrowia lipolytica

Products Thermo Fisher Scientific Gal-Screen™ β-Galactosidase Reporter Gene Assay System for Mammalian Cells

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD171/L1CAM

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD49f/ITGA6

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms