DNA quantification Human

- Found 5526 results

Get tips on using PE-Cy™7 Mouse Anti-Human CD123 to perform Flow cytometry Anti-bodies Human - CD123/IL3-R

Products BD Biosciences PE-Cy™7 Mouse Anti-Human CD123

Get tips on using Accell Human VDAC1 (7416) siRNA - Set of 4 to perform siRNA / miRNA gene silencing Human - HCT-116 VDAC1

Products Dharmacon Accell Human VDAC1 (7416) siRNA - Set of 4

Get tips on using Accell Human VDAC1 (7416) siRNA - Set of 4 to perform siRNA / miRNA gene silencing Human - Min-6 VDAC1

Products Dharmacon Accell Human VDAC1 (7416) siRNA - Set of 4

Get tips on using Accell Human VDAC1 (7416) siRNA - Set of 4 to perform siRNA / miRNA gene silencing Human - PC-3 VDAC1

Products Dharmacon Accell Human VDAC1 (7416) siRNA - Set of 4

Get tips on using Accell Human VDAC1 (7416) siRNA - Set of 4 to perform siRNA / miRNA gene silencing Human - PANC-1 VDAC1

Products Dharmacon Accell Human VDAC1 (7416) siRNA - Set of 4

Get tips on using GeneChip® Human Genome U133 Plus 2.0 Array to perform Microarray Human - Precision cut lung slices Expression array

Products Thermo Fisher Scientific GeneChip® Human Genome U133 Plus 2.0 Array

Get tips on using Monoclonal Mouse Anti-Human CDX2 (Dako Omnis) Clone DAK-CDX2 to perform Immunohistochemistry Human - CDX2

Products Agilent Technologies Monoclonal Mouse Anti-Human CDX2 (Dako Omnis) Clone DAK-CDX2

Get tips on using ON-TARGETplus Human BSG / emmprin (682) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Human - BCP-1 Emmprin / BSG

Products Dharmacon ON-TARGETplus Human BSG / emmprin (682) siRNA - SMARTpool

Get tips on using GeneChip® Human Genome U133 Plus 2.0 Array to perform Microarray Gene expression arrays - Human endometrial stromal cells Biotin

Products Thermo Fisher Scientific GeneChip® Human Genome U133 Plus 2.0 Array

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human SH-SY5Y

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms