DNA methylation profiling Gene specific profiling Whole blood (human)

- Found 6376 results

Get tips on using SurePrint G3 Human CGH Microarray Kit, 4x180K to perform Microarray Comperative genomic hybridization - Human SH-SY5Y

Products Agilent Technologies SurePrint G3 Human CGH Microarray Kit, 4x180K

Get tips on using SurePrint G3 Human CGH Microarray Kit, 2x400K to perform Microarray Comperative genomic hybridization - Human U-251

Products Agilent Technologies SurePrint G3 Human CGH Microarray Kit, 2x400K

Get tips on using SurePrint G3 Human CGH Microarray Kit, 4x180K to perform Microarray Comperative genomic hybridization - Human Bone marrow

Products Agilent Technologies SurePrint G3 Human CGH Microarray Kit, 4x180K

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Human Point mutation SKOV3 humanized trastuzumab

Get tips on using SurePrint G3 Human CGH Microarray Kit, 4x180K to perform Microarray Comperative genomic hybridization - Human MDA-MB-361

Products Agilent Technologies SurePrint G3 Human CGH Microarray Kit, 4x180K

Get tips on using SurePrint G3 Human CGH Microarray Kit, 4x180K to perform Microarray Comperative genomic hybridization - Human MDA-MB-453

Products Agilent Technologies SurePrint G3 Human CGH Microarray Kit, 4x180K

ROS has a very short half-lives in biological environment as they are influenced by exposure to ambient oxygen. As it is highly reactive and hard to measure care should be taken to ensure the stability of the sample during isolation, preparation, storage, and analysis.

Cellular assays ROS assay cell type A549 human adenocarcinomic human alveolar basal epithelial cells

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human SH-SY5Y

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human MCF-7

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human SKBR-3

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms