rna-isolation-purification-cells-primary-rat-brain-microvascular-endothelial-cells

- Found 9027 results

Get tips on using AllPrep Bacterial DNA/RNA/Protein Kit (50) to perform DNA isolation / purification Bacteria - Gram negative Massilia sp

Products Qiagen AllPrep Bacterial DNA/RNA/Protein Kit (50)

Get tips on using EpiTect Fast 96 Bisulfite Kit to perform Bisulfite DNA Modification Cell lines / primary cells

Products Qiagen EpiTect Fast 96 Bisulfite Kit

Get tips on using EpiTect Fast Bisulfite Kit (10) to perform Bisulfite DNA Modification Cell lines / primary cells

Products Qiagen EpiTect Fast Bisulfite Kit (10)

Get tips on using EpiTect Plus DNA Bisulfite Kit to perform Bisulfite DNA Modification Cell lines / primary cells

Products Qiagen EpiTect Plus DNA Bisulfite Kit

Get tips on using Rat GE 4x44K v3 Microarray Kit to perform Microarray Gene expression arrays - Rat pancreas tissue Cyanine 3 & cyanine 5

Products Agilent Technologies Rat GE 4x44K v3 Microarray Kit

Get tips on using Rat GE 4x44K v3 Microarray Kit to perform Microarray Gene expression arrays - Rat cholangio carcinoma cyanine 3 & cyanine 5

Products Agilent Technologies Rat GE 4x44K v3 Microarray Kit

Short hairpin or small hairpin RNA (shRNA) is artificial RNA, which has a hairpin loop structure, and uses inherent microRNA (miRNA) machinery to silence target gene expression. This is called RNA interference (RNAi). These can be delivered via plasmids or viral/bacterial vectors. Challenges in shRNA-mediated gene silencing include: 1. Off-target silencing, 2. Packaging shRNA encoding lentivirus, and 3. Stable transduction in cells. RNAi have been designed to have anywhere from 19-27 bs, but the most effective design has 19 bp. In case commercial shRNAs are not available, potential target sites can be chosen within exon, 5’- or 3’ UTR, depending on which splice variants of the gene are desired. One should use the latest algorithms and choose at least two different sequences, targeting different regions, in order to have confidence in overcoming off-target effects. A BLAST search after selecting potential design will eliminate potential off-target sequences. For the second challenge, sequencing the vector using primers for either strand (50-100 bp upstream) is suggested, along with using enzymatic digestion on agarose gel for the vector. Next, once the shRNA-containing vector is packaged in a virus, it is important to check the viral titer before transduction. Finally, using a marker in the lentiviral vector (fluorescent protein or antibiotic resistance), along with qPCR for target gene expression can help in determining efficacy of transduction and shRNA on its target site.

RNA shRNA gene silencing Human Neuroblastoma cells (SH-SY5Y) Connexin 43 lentiviral particles

Get tips on using Blood & Cell Culture DNA Midi Kit (25) to perform DNA isolation / purification Cells - Immortalized cell lines Human Neuroblastoma Cell Lines

Products Qiagen Blood & Cell Culture DNA Midi Kit (25)

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Rat Adiponectin

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Rat Activin

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms