DNA Damage Assay

- Found 4720 results

Get tips on using PE Annexin V Apoptosis Detection Kit with 7-AAD to perform Apoptosis assay cell type - T-cells Mouse (OT-I)

Products BD Biosciences PE Annexin V Apoptosis Detection Kit with 7-AAD

Get tips on using Click-iT™ EdU Alexa Fluor™ 555 Imaging Kit to perform Cell cytotoxicity / Proliferation assay cell type - PC-3

Products Thermo Fisher Scientific Click-iT™ EdU Alexa Fluor™ 555 Imaging Kit

Get tips on using Image-IT™ LIVE Green Reactive Oxygen Species Detection Kit, for microscopy to perform ROS assay cell type - MCF-7

Products Thermo Fisher Scientific Image-IT™ LIVE Green Reactive Oxygen Species Detection Kit, for microscopy

Get tips on using Purified Mouse Anti-p62 Ick ligand Clone 3/P62 LCK LIGAND (RUO) to perform Autophagy assay cell type - THP 1

Products BD Biosciences Purified Mouse Anti-p62 Ick ligand Clone 3/P62 LCK LIGAND (RUO)

Get tips on using Purified Mouse Anti-p62 Ick ligand Clone 3/P62 LCK LIGAND (RUO) to perform Autophagy assay cell type - SH-SY5Y

Products BD Biosciences Purified Mouse Anti-p62 Ick ligand Clone 3/P62 LCK LIGAND (RUO)

Get tips on using D,L-Sulforaphane N-Acetyl-L-cysteine (SFN-NAC) (CAS 334829-66-2) to perform Autophagy assay cell type - U373MG

Products Santa Cruz Biotechnology D,L-Sulforaphane N-Acetyl-L-cysteine (SFN-NAC) (CAS 334829-66-2)

The most widely used method for protein quantification is by spectrophotometry. The concentration of the protein in the samples is measured at an absorbance of 280 nm. The absorbance of the sample protein is then plotted against a standard curve. This method allows for total protein quantification in a sample (cell and tissue extracts). Before analysing the concentration of protein in the sample, it is important to choose the right test method.  For high protein concentration samples (above 5 - 160 mg/ml) the best method is to use the Biuret test. For low concentrations samples (between 1 - 2000µg/ml) the best methods are Lowry assay, BCA assay, Bradford assay and coomassie blue (for exact sensitivity of the test kits you use, refer to manufacturer's protocol). If the samples contain detergents like Triton X-100 then BCA assay is the best choice. For samples that have proteins larger than 3 KDa in size Bradford assay is the best choice. Each method has advantages and disadvantages, plan your analysis considering your sample characteristics.

Proteins Protein quantification Colorimetric method

The most widely used method for protein quantification is by spectrophotometry. The concentration of the protein in the samples is measured at an absorbance of 280 nm. The absorbance of the sample protein is then plotted against a standard curve. This method allows for total protein quantification in a sample (cell and tissue extracts). Before analysing the concentration of protein in the sample, it is important to choose the right test method.  For high protein concentration samples (above 5 - 160 mg/ml) the best method is to use the Biuret test. For low concentrations samples (between 1 - 2000µg/ml) the best methods are Lowry assay, BCA assay, Bradford assay and coomassie blue (for exact sensitivity of the test kits you use, refer to manufacturer's protocol). If the samples contain detergents like Triton X-100 then BCA assay is the best choice. For samples that have proteins larger than 3 KDa in size Bradford assay is the best choice. Each method has advantages and disadvantages, plan your analysis considering your sample characteristics.

Proteins Protein quantification Fluorimetric method

DNA microarrays enable researchers to monitor the expression of thousands of genes simultaneously. However, the sensitivity, accuracy, specificity, and reproducibility are major challenges for this technology. Cross-hybridization, combination with splice variants, is a prime source for the discrepancies in differential gene expression calls among various microarray platforms. Removing (either from production or downstream bioinformatic analysis) and/or redesigning the microarray probes prone to cross-hybridization is a reasonable strategy to increase the hybridization specificity and hence, the accuracy of the microarray measurements.

DNA Microarray Gene expression arrays Rat mesothelium Satin cocktail

DNA microarrays enable researchers to monitor the expression of thousands of genes simultaneously. However, the sensitivity, accuracy, specificity, and reproducibility are major challenges for this technology. Cross-hybridization, combination with splice variants, is a prime source for the discrepancies in differential gene expression calls among various microarray platforms. Removing (either from production or downstream bioinformatic analysis) and/or redesigning the microarray probes prone to cross-hybridization is a reasonable strategy to increase the hybridization specificity and hence, the accuracy of the microarray measurements.

DNA Microarray Gene expression arrays Mouse dorsal skin Biotin

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms