Protein Expression Prokaryotic cells C. crescentus JS1014

- Found 8982 results

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD110/Thrombopoietin R

Get tips on using SV Total RNA Isolation System to perform RNA isolation / purification Cells - primary human coronary artery smooth muscle cells

Products Promega SV Total RNA Isolation System

Get tips on using TransIT®-LT1 Transfection Reagent to perform siRNA / RNAi /miRNA transfection Human Cells - Cal 27 cells Polymer / lipid

Products Mirus TransIT®-LT1 Transfection Reagent

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse Ly-6A-E/Sca1

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse Ly6C/Gr-1/Ly6G

Get tips on using E.Z.N.A.® Total RNA Kit I to perform RNA isolation / purification Cells - primary bovine umbilical vein endothelial cells

Products Omega Bio Tek E.Z.N.A.® Total RNA Kit I

Get tips on using Wizard® Genomic DNA Purification Kit to perform DNA isolation / purification Cells - Primary cells Mouse embryonic fibroblast (MEF)

Products Promega Wizard® Genomic DNA Purification Kit

Get tips on using jetPEI® DNA transfection, HTS application to perform DNA transfection Mammalian cells - Primary cells Rat dermal fibroblasts (rDF)

Products Polyplus transfections jetPEI® DNA transfection, HTS application

Get tips on using Zombie Aqua™ Fixable Viability Kit to perform Live / Dead assay mammalian cells - human peripheral blood mononuclear cells

Products BioLegend Zombie Aqua™ Fixable Viability Kit

Get tips on using GenElute™ Mammalian Total RNA Miniprep Kit to perform RNA isolation / purification Cells - primary human pancreatic stellate cells

Products Sigma-Aldrich GenElute™ Mammalian Total RNA Miniprep Kit

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms