DNA methylation profiling Gene specific profiling Ca Ski

- Found 5852 results

When extracting nucleic acids from cell cultures, thorough homogenization of cells via vortexing in lysis buffer is very necessary. Choose the best RNA isolation method keeping in mind the downstream applications, generally, column-based isolations result in clean and concentrated RNA samples. Downstream applications like sequencing and cDNA synthesis require high-quality RNA, always treat the samples with DNases and check their integrity by running a gel.

RNA RNA isolation / purification Cells immortalized SiHa

Get tips on using Nucleofector™ Kits for Human T Cells to perform DNA transfection Mammalian cells - Primary cells CD8+ T cells

Products Lonza Nucleofector™ Kits for Human T Cells

Get tips on using Nucleofector™ Kits for Human T Cells to perform DNA transfection Mammalian cells - Primary cells CD4+ T cells

Products Lonza Nucleofector™ Kits for Human T Cells

Get tips on using MagNA Pure Compact Nucleic Acid Isolation Kit I to perform DNA isolation / purification Bacteria - Gram negative Salmonella enterica

Products Roche Lifesciences MagNA Pure Compact Nucleic Acid Isolation Kit I

Get tips on using MagNA Pure Compact Nucleic Acid Isolation Kit I to perform DNA isolation / purification Bacteria - Gram negative Helicobacter pylori

Products Roche Lifesciences MagNA Pure Compact Nucleic Acid Isolation Kit I

Get tips on using MagNA Pure Compact Nucleic Acid Isolation Kit I to perform DNA isolation / purification Bacteria - Gram negative Pseudomonas aeruginosa

Products Roche Lifesciences MagNA Pure Compact Nucleic Acid Isolation Kit I

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Human Adiponectin

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Human BMP-2

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Human BDNF

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Human BRCA2

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms