siRNA / miRNA gene silencing Human HNSCC cell line Eph receptor B4

- Found 8975 results

Get tips on using Mammalian beta-Galactosidase Assay Kit to perform Reporter gene assay β-galactosidase substrates - Aspc-1

Products Thermo Fisher Scientific Mammalian beta-Galactosidase Assay Kit

Get tips on using Mammalian beta-Galactosidase Assay Kit to perform Reporter gene assay β-galactosidase substrates - Bxpc-3

Products Thermo Fisher Scientific Mammalian beta-Galactosidase Assay Kit

Get tips on using Beta-Glo® Assay System to perform Reporter gene assay β-galactosidase substrates - PANC-1

Products Promega Beta-Glo® Assay System

Get tips on using Luminescent β-galactosidase Detection Kit II to perform Reporter gene assay β-galactosidase substrates - CHO

Products Takara Bio Inc Luminescent β-galactosidase Detection Kit II

Get tips on using Senescence β-Galactosidase Staining Kit - Beyotime to perform Reporter gene assay β-galactosidase substrates - HepG2

Products Beyotime Senescence β-Galactosidase Staining Kit - Beyotime

Get tips on using Luminescent β-galactosidase Detection Kit II to perform Reporter gene assay β-galactosidase substrates - H1299

Products Takara Bio Inc Luminescent β-galactosidase Detection Kit II

Get tips on using Luminescent β-galactosidase Detection Kit II to perform Reporter gene assay β-galactosidase substrates - U2OS

Products Takara Bio Inc Luminescent β-galactosidase Detection Kit II

Get tips on using Cellstain-Double Staining Kit to perform Live / Dead assay mammalian cells - HepaRG human hepatoma

Products Dojindo Cellstain-Double Staining Kit

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD326/EpCAM

Get tips on using miRNeasy Mini kit to perform RNA isolation / purification Cells - immortalized Sf9

Products Qiagen miRNeasy Mini kit

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms