Contamination can affect cell characteristics, i.e., growth, metabolism, and morphology leading to unreliable and erroneous experimental data. Depending on the source of contaminants, one can detect contamination by using a light microscope, gram stain, isothermal amplification, or PCR. Bacteria and fungi can usually be identified by optical microscopy. Mycoplasma in cell cultures cannot be detected visually. Hence, these microbes can go unnoticed for long periods and are determined using dedicated assays. Early and rapid identification of contaminants is vital to detect, handle and prevent contamination for good cell-culture practices. However, detection and identification can be challenging and tricky based on usual visual identifications. Hence it is essential to use a standard contamination detection kit to detect and maintain best practices.
ROS has a very short half-lives in biological environment as they are influenced by exposure to ambient oxygen. As it is highly reactive and hard to measure care should be taken to ensure the stability of the sample during isolation, preparation, storage, and analysis.
As autophagy is a multi-step process which includes not just the formation of autophagosomes, but most importantly, flux through the entire system, including the degradation upon fusion with lysosomes, which makes it quite challenging for detection. There are several methods for detection in mammalian cells, including immunoblotting analysis of LC3 and p62 and detection of autophagosome formation/maturation by fluorescence microscopy, Currently, there is no single “gold standard” for determining the autophagic activity that is applicable in every experimental context, hence it is recommended to go for the combined use of multiple methods to accurately assess the autophagic activity in any given biological setting.
Get tips on using Reactive Oxygen Species (ROS) Detection Assay Kit to perform ROS assay cell type - PLHC-1, SK-HEP-1, Hep3b, HepG2 human hepatocellular carcinoma
Get tips on using Remel™ PathoDX™ Herpes Typing Kit, PathoDx™ Herpes Typing Kit to perform Cell Culture Contamination Detection Kit Virus
Get tips on using ROS-ID® Total ROS/Superoxide detection kit to perform ROS assay cell type - PLHC-1, SK-HEP-1, Hep3b, HepG2 human hepatocellular carcinoma
Get tips on using OxiSelect™ Intracellular ROS Assay Kit (Green Fluorescence) to perform ROS assay cell type - PLHC-1, SK-HEP-1, Hep3b, HepG2 human hepatocellular carcinoma
Get tips on using DCFDA - Cellular Reactive Oxygen Species Detection Assay Kit to perform ROS assay cell type - PLHC-1, SK-HEP-1, Hep3b, HepG2 human hepatocellular carcinoma
Get tips on using OxiSelect™ In Vitro ROS/RNS Assay Kit (Green Fluorescence) to perform ROS assay cell type - PLHC-1, SK-HEP-1, Hep3b, HepG2 human hepatocellular carcinoma
Generally isolating RNA from Gram-negative bacteria is easy, however keeping your working environment clean and RNase free (use RNase inhibitor) is essential. Some common points to keep in mind: a) Use fresh samples for isolation or store them by freezing in RNA stabilizing buffer until use. b) Choose the bacterial input amounts carefully, to ensure buffer volumes are adequate and not to overload the columns.
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment