Get tips on using DIA-310: Anti-CD31 (Ms) from Rat (Clone: SZ31) for mouse FFPE tissue to perform Immunohistochemistry CD31 - Rabbit Rat -NA-
Get tips on using Dead Cell Apoptosis Kit with Annexin V Alexa Fluor™ 488 & Propidium Iodide (PI) to perform Apoptosis assay cell type - RPMI-8226
Get tips on using Dead Cell Apoptosis Kit with Annexin V Alexa Fluor™ 488 & Propidium Iodide (PI) to perform Apoptosis assay cell type - SH-SY5Y
Get tips on using Dead Cell Apoptosis Kit with Annexin V Alexa Fluor™ 488 & Propidium Iodide (PI) to perform Apoptosis assay cell type - HeLa cells
Hello everyone! I am going to do a live/dead assay for my cells and I saw that I can use both fluorescence and absorbance as my detection method. Is there a difference in the results depending on the method? Is one method preferred over the other in certain situations?
The most widely used method for protein quantification is by spectrophotometry. The concentration of the protein in the samples is measured at an absorbance of 280 nm. The absorbance of the sample protein is then plotted against a standard curve. This method allows for total protein quantification in a sample (cell and tissue extracts). Before analysing the concentration of protein in the sample, it is important to choose the right test method. For high protein concentration samples (above 5 - 160 mg/ml) the best method is to use the Biuret test. For low concentrations samples (between 1 - 2000µg/ml) the best methods are Lowry assay, BCA assay, Bradford assay and coomassie blue (for exact sensitivity of the test kits you use, refer to manufacturer's protocol). If the samples contain detergents like Triton X-100 then BCA assay is the best choice. For samples that have proteins larger than 3 KDa in size Bradford assay is the best choice. Each method has advantages and disadvantages, plan your analysis considering your sample characteristics.
The most widely used method for protein quantification is by spectrophotometry. The concentration of the protein in the samples is measured at an absorbance of 280 nm. The absorbance of the sample protein is then plotted against a standard curve. This method allows for total protein quantification in a sample (cell and tissue extracts). Before analysing the concentration of protein in the sample, it is important to choose the right test method. For high protein concentration samples (above 5 - 160 mg/ml) the best method is to use the Biuret test. For low concentrations samples (between 1 - 2000µg/ml) the best methods are Lowry assay, BCA assay, Bradford assay and coomassie blue (for exact sensitivity of the test kits you use, refer to manufacturer's protocol). If the samples contain detergents like Triton X-100 then BCA assay is the best choice. For samples that have proteins larger than 3 KDa in size Bradford assay is the best choice. Each method has advantages and disadvantages, plan your analysis considering your sample characteristics.
Gene silencing through the use of small interfering RNA (siRNA) has become a primary tool for identifying disease-causing genes. There are several aspects for preparing and delivering effective siRNA to knockdown a target gene. The length of siRNA should be 21–23nt long with G/C content 30–50%. If a validated siRNA sequence for your target gene is not available, use siRNA generated against the entire target gene ORF. Always work with two or three different siRNA constructs to get reliable results. If you are not sure how much siRNA to use for a given experiment, start with a transfection concentration of 10-50 nM and use siRNA-specific transfection reagent to ensure efficient siRNA delivery in a wide range of cells.
Get tips on using Cytotoxicity Detection Kit (LDH) to perform Live / Dead assay bacteria - Pseudomonas aeruginosa
Get tips on using Cell Counting Kit-8 to perform Live / Dead assay mammalian cells - GH3
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment