rna-isolation-purification-cells-immortalized-mda-mb-361

- Found 9121 results

Get tips on using Oligofectamine™ Transfection Reagent to perform siRNA / RNAi /miRNA transfection Rat - A-10 Cationic lipid based

Products Thermo Fisher Scientific Oligofectamine™ Transfection Reagent

Get tips on using Xfect™ Transfection Reagent to perform siRNA / RNAi /miRNA transfection Rat - H9c2 Cationic and neutral lipids

Products Takara Bio Inc Xfect™ Transfection Reagent

Get tips on using Lipofectamine® 2000 Transfection Reagent to perform siRNA / RNAi /miRNA transfection Rat - IEC-6 Lipofectamine

Products Thermo Fisher Scientific Lipofectamine® 2000 Transfection Reagent

Get tips on using X-tremeGENE™ siRNA Transfection Reagent to perform siRNA / RNAi /miRNA transfection Rat - AR42J Lipid based

Products Sigma-Aldrich X-tremeGENE™ siRNA Transfection Reagent

RNA siRNA / miRNA gene silencing Human 501 Mel and SK Mel 28 FANCD2 Polymer / Lipid

Get tips on using HiPerFect Transfection Reagent (100 ml) to perform siRNA / RNAi /miRNA transfection Bovine - monocyte-derived macrophages

Products Qiagen HiPerFect Transfection Reagent (100 ml)

As autophagy is a multi-step process which includes not just the formation of autophagosomes, but most importantly, flux through the entire system, including the degradation upon fusion with lysosomes, which makes it quite challenging for detection. There are several methods for detection in mammalian cells, including immunoblotting analysis of LC3 and p62 and detection of autophagosome formation/maturation by fluorescence microscopy, Currently, there is no single “gold standard” for determining the autophagic activity that is applicable in every experimental context, hence it is recommended to go for the combined use of multiple methods to accurately assess the autophagic activity in any given biological setting.

Cellular assays Autophagy assay cell type Myelodysplastic (MDS‐L)

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay bacteria Bacillus subtilis

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay bacteria Borrelia burgdorferi

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay bacteria Staphylococcus aureus

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms