reporter-gene-assay-luciferase-bhk-21-baby-hamster-kidney-cells

- Found 7741 results

Reporter gene assays enable high sensitivity measurement of gene expression and cell signaling through the addition of bioluminescent genes into target cells. One of the major challenges is to make a specific construct that has no responses other than those related to the signaling pathway of interest. This can be achieved by selecting highly specific reporter constructs containing only defined responsive elements and a minimal promoter linked to reporter enzymes such as luciferase

Cellular assays Reporter gene assay β-galactosidase substrates HEK293 human embryonic kidney cells

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Hamster Point mutation BHK-21 DENV4

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Hamster Point mutation BHK-21 PI4KA

Get tips on using SuperLight™ Dual Luciferase Reporter Gene Assay Kit to perform Reporter gene assay luciferase - HepG2 and Huh7 cells

Products Bio Trend SuperLight™ Dual Luciferase Reporter Gene Assay Kit

Reporter gene assays enable high sensitivity measurement of gene expression and cell signaling through the addition of bioluminescent genes into target cells. One of the major challenges is to make a specific construct that has no responses other than those related to the signaling pathway of interest. This can be achieved by selecting highly specific reporter constructs containing only defined responsive elements and a minimal promoter linked to reporter enzymes such as luciferase

Cellular assays Reporter gene assay luciferase SW480 human colon cancer cell line

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Hamster Point mutation BHK-21 LCMV (lymphocytic choriomeningitis virus)

Get tips on using Dual-Light™ Luciferase & β-Galactosidase Reporter Gene Assay System to perform Reporter gene assay β-galactosidase substrates - Hep3B

Products Thermo Fisher Scientific Dual-Light™ Luciferase & β-Galactosidase Reporter Gene Assay System

Get tips on using Dual-Light™ Luciferase & β-Galactosidase Reporter Gene Assay System to perform Reporter gene assay β-galactosidase substrates - U2OS

Products Thermo Fisher Scientific Dual-Light™ Luciferase & β-Galactosidase Reporter Gene Assay System

Get tips on using Dual-Luciferase® Reporter Assay System to perform Reporter gene assay luciferase - primary human endometrial stromal cells

Products Promega Dual-Luciferase® Reporter Assay System

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells BHK-21

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms