siRNA / miRNA gene silencing Human MCF-7

- Found 5320 results

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human A413

Get tips on using BLOCK-iT™ Adenoviral RNAi Expression System, pAd/BLOCK-iT™-DEST RNAi Gateway Vector to perform shRNA gene silencing Mouse - P19 Foxm1

Products Thermo Fisher Scientific BLOCK-iT™ Adenoviral RNAi Expression System, pAd/BLOCK-iT™-DEST RNAi Gateway Vector

DNA microarrays enable researchers to monitor the expression of thousands of genes simultaneously. However, the sensitivity, accuracy, specificity, and reproducibility are major challenges for this technology. Cross-hybridization, combination with splice variants, is a prime source for the discrepancies in differential gene expression calls among various microarray platforms. Removing (either from production or downstream bioinformatic analysis) and/or redesigning the microarray probes prone to cross-hybridization is a reasonable strategy to increase the hybridization specificity and hence, the accuracy of the microarray measurements.

DNA Microarray Gene expression arrays Rat pancreas tissue Cyanine 3 & cyanine 5

Get tips on using Galacto-Light Plus™ β-Galactosidase Reporter Gene Assay System to perform Reporter gene assay β-galactosidase substrates - C2C12

Products Thermo Fisher Scientific Galacto-Light Plus™ β-Galactosidase Reporter Gene Assay System

Get tips on using Dual-Light™ Luciferase & β-Galactosidase Reporter Gene Assay System to perform Reporter gene assay β-galactosidase substrates - Hep3B

Products Thermo Fisher Scientific Dual-Light™ Luciferase & β-Galactosidase Reporter Gene Assay System

Get tips on using Dual-Light™ Luciferase & β-Galactosidase Reporter Gene Assay System to perform Reporter gene assay β-galactosidase substrates - U2OS

Products Thermo Fisher Scientific Dual-Light™ Luciferase & β-Galactosidase Reporter Gene Assay System

Get tips on using Galacto-Light Plus™ β-Galactosidase Reporter Gene Assay System to perform Reporter gene assay β-galactosidase substrates - CHO-K1

Products Thermo Fisher Scientific Galacto-Light Plus™ β-Galactosidase Reporter Gene Assay System

Get tips on using Galacto-Light Plus™ β-Galactosidase Reporter Gene Assay System to perform Reporter gene assay β-galactosidase substrates - RAW 264.7

Products Thermo Fisher Scientific Galacto-Light Plus™ β-Galactosidase Reporter Gene Assay System

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human SH-SY5Y

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human SKBR-3

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms