Site Directed Mutagenesis (SDM) Monkey Deletion COS-7

- Found 5850 results

The most widely used method for protein quantification is by spectrophotometry. The concentration of the protein in the samples is measured at an absorbance of 280 nm. The absorbance of the sample protein is then plotted against a standard curve. This method allows for total protein quantification in a sample (cell and tissue extracts). Before analysing the concentration of protein in the sample, it is important to choose the right test method.  For high protein concentration samples (above 5 - 160 mg/ml) the best method is to use the Biuret test. For low concentrations samples (between 1 - 2000µg/ml) the best methods are Lowry assay, BCA assay, Bradford assay and coomassie blue (for exact sensitivity of the test kits you use, refer to manufacturer's protocol). If the samples contain detergents like Triton X-100 then BCA assay is the best choice. For samples that have proteins larger than 3 KDa in size Bradford assay is the best choice. Each method has advantages and disadvantages, plan your analysis considering your sample characteristics.

Proteins Protein quantification Fluorimetric method

Get tips on using CardioTACS™ In Situ Apoptosis Detection Kit to perform Apoptosis assay cell type - Cardiomyocytes

Products Bio-Techne CardioTACS™ In Situ Apoptosis Detection Kit

Get tips on using In Situ Cell Death Detection Kit, Fluorescein to perform Apoptosis assay cell type - HUVEC

Products Sigma-Aldrich In Situ Cell Death Detection Kit, Fluorescein

Cell cytotoxicity assays measure the ability of certain compounds or chemical mediators to reduce the viability of the cells. The term cell cytotoxicity assay can sometimes be used interchangeably with cell proliferation assay. Healthy living cells can be identified by the use of formazan dyes, protease biomarkers or by measuring ATP content. The formazan dyes are chromogenic products formed by the reduction of tetrazolium salts by dehydrogenases, such as lactate dehydrogenase (LDH) and reductases that are released during cell death. Common tetrazolium salts include INT, MTT, MTS and XTT. Cell cytotoxicity can also be measured by using the SRB and WST-1 assays. These assays can usually be used in a high-throughput fashion and can be quantitated by measuring absorbance, colorimetry or luminescence. All these assays require similar numbers of cell plating at the initiation, a time course of treatment with the cytotoxic agent and at least triplicates for each condition at every point of analysis. Cell shrinkage, plasma membrane blebbing, cell detachment, externalization of phosphatidylserine, nuclear condensation and ultimately DNA fragmentation are well-described features of apoptosis. The assays that rely on cell membrane integrity for their function, may not be able to quantify early apoptosis. Therefore, in order to distinguish early apoptotic vs. late apoptotic or necrotic cells, additional flow cytometry techniques can be used. A combination of Annexin V and PI (propidium iodide) can be used to distinguish early (Annexin V+/PI-) and late apoptotic (Annexin V+/PI+) cells. Sometimes, caspase assays are used in order to differentiate the stages of apoptosis.

Cellular assays Cell cytotoxicity / Proliferation assay cell type LTEP-a-2 lung adenocarcenoma

Cell cytotoxicity assays measure the ability of certain compounds or chemical mediators to reduce the viability of the cells. The term cell cytotoxicity assay can sometimes be used interchangeably with cell proliferation assay. Healthy living cells can be identified by the use of formazan dyes, protease biomarkers or by measuring ATP content. The formazan dyes are chromogenic products formed by the reduction of tetrazolium salts by dehydrogenases, such as lactate dehydrogenase (LDH) and reductases that are released during cell death. Common tetrazolium salts include INT, MTT, MTS and XTT. Cell cytotoxicity can also be measured by using the SRB and WST-1 assays. These assays can usually be used in a high-throughput fashion and can be quantitated by measuring absorbance, colorimetry or luminescence. All these assays require similar numbers of cell plating at the initiation, a time course of treatment with the cytotoxic agent and at least triplicates for each condition at every point of analysis. Cell shrinkage, plasma membrane blebbing, cell detachment, externalization of phosphatidylserine, nuclear condensation and ultimately DNA fragmentation are well-described features of apoptosis. The assays that rely on cell membrane integrity for their function, may not be able to quantify early apoptosis. Therefore, in order to distinguish early apoptotic vs. late apoptotic or necrotic cells, additional flow cytometry techniques can be used. A combination of Annexin V and PI (propidium iodide) can be used to distinguish early (Annexin V+/PI-) and late apoptotic (Annexin V+/PI+) cells. Sometimes, caspase assays are used in order to differentiate the stages of apoptosis.

Cellular assays Cell cytotoxicity / Proliferation assay cell type MDA-MB-231 breast adenocarcenoma

Get tips on using VasoTACS™ In Situ Apoptosis Detection Kit to perform TUNEL assay cell type - Mouse endothelial cells

Products Bio-Techne VasoTACS™ In Situ Apoptosis Detection Kit

Get tips on using ApopTag® Peroxidase In Situ Apoptosis Detection Kit to perform Apoptosis assay cell type - HEK293

Products Millipore ApopTag® Peroxidase In Situ Apoptosis Detection Kit

Get tips on using TumorTACS™ In Situ Apoptosis Detection Kit to perform TUNEL assay cell type - Mouse liver tissue

Products Bio-Techne TumorTACS™ In Situ Apoptosis Detection Kit

Get tips on using In Situ Cell Death Detection Kit, Fluorescein to perform TUNEL assay cell type - Mouse liver tissue

Products Sigma-Aldrich In Situ Cell Death Detection Kit, Fluorescein

Get tips on using TdT In Situ Apoptosis Detection Kit - Fluorescein to perform TUNEL assay cell type - Rat fibroblast-like synoviocytes

Products R&D system, Minneapolis, MN, USA TdT In Situ Apoptosis Detection Kit - Fluorescein

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms