Get tips on using CellROX™ Deep Red Reagent, for oxidative stress detection to perform ROS assay cell type - PANC-, BxPC-3 human pancreas
Get tips on using LIVE/DEAD™ Viability/Cytotoxicity Kit, for mammalian cells to perform Live / Dead assay mammalian cells - SH-SY5Y Human neuroblastoma
Get tips on using FragEL™ DNA Fragmentation Detection Kit, Colorimetric - TdT Enzyme to perform TUNEL assay cell type - 3T3 L1 mouse adipose tissue
Get tips on using Click-iT™ EdU Alexa Fluor™ 555 Imaging Kit to perform Cell cytotoxicity / Proliferation assay cell type - PC-3
Get tips on using Image-IT™ LIVE Green Reactive Oxygen Species Detection Kit, for microscopy to perform ROS assay cell type - MCF-7
Get tips on using Purified Mouse Anti-p62 Ick ligand Clone 3/P62 LCK LIGAND (RUO) to perform Autophagy assay cell type - THP 1
Get tips on using Purified Mouse Anti-p62 Ick ligand Clone 3/P62 LCK LIGAND (RUO) to perform Autophagy assay cell type - SH-SY5Y
Get tips on using D,L-Sulforaphane N-Acetyl-L-cysteine (SFN-NAC) (CAS 334829-66-2) to perform Autophagy assay cell type - U373MG
The most widely used method for protein quantification is by spectrophotometry. The concentration of the protein in the samples is measured at an absorbance of 280 nm. The absorbance of the sample protein is then plotted against a standard curve. This method allows for total protein quantification in a sample (cell and tissue extracts). Before analysing the concentration of protein in the sample, it is important to choose the right test method. For high protein concentration samples (above 5 - 160 mg/ml) the best method is to use the Biuret test. For low concentrations samples (between 1 - 2000µg/ml) the best methods are Lowry assay, BCA assay, Bradford assay and coomassie blue (for exact sensitivity of the test kits you use, refer to manufacturer's protocol). If the samples contain detergents like Triton X-100 then BCA assay is the best choice. For samples that have proteins larger than 3 KDa in size Bradford assay is the best choice. Each method has advantages and disadvantages, plan your analysis considering your sample characteristics.
The most widely used method for protein quantification is by spectrophotometry. The concentration of the protein in the samples is measured at an absorbance of 280 nm. The absorbance of the sample protein is then plotted against a standard curve. This method allows for total protein quantification in a sample (cell and tissue extracts). Before analysing the concentration of protein in the sample, it is important to choose the right test method. For high protein concentration samples (above 5 - 160 mg/ml) the best method is to use the Biuret test. For low concentrations samples (between 1 - 2000µg/ml) the best methods are Lowry assay, BCA assay, Bradford assay and coomassie blue (for exact sensitivity of the test kits you use, refer to manufacturer's protocol). If the samples contain detergents like Triton X-100 then BCA assay is the best choice. For samples that have proteins larger than 3 KDa in size Bradford assay is the best choice. Each method has advantages and disadvantages, plan your analysis considering your sample characteristics.
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment