Flowcytometry CD3 Mouse / IgG1, kappa Human

- Found 5099 results

Get tips on using Purified Rat Anti-Mouse CD24 Clone M1/69 (RUO) to perform Immunohistochemistry Mouse - CD24

Products BD Biosciences Purified Rat Anti-Mouse CD24 Clone M1/69 (RUO)

Get tips on using Purified Mouse Anti-E-Cadherin Clone 36/E-Cadherin (RUO) to perform Immunohistochemistry Human - E-Cadherin

Products BD Biosciences Purified Mouse Anti-E-Cadherin Clone 36/E-Cadherin (RUO)

Get tips on using Monoclonal Mouse Anti-Thyroid Transcription Factor (Concentrate) Clone 8G7G3/1 to perform Immunohistochemistry Human - TTF-1

Products Agilent Technologies Monoclonal Mouse Anti-Thyroid Transcription Factor (Concentrate) Clone 8G7G3/1

Get tips on using Purified Mouse Anti-β-Catenin Clone 14/Beta-Catenin (RUO) to perform Immunohistochemistry Human - β-catenin

Products BD Biosciences Purified Mouse Anti-β-Catenin Clone 14/Beta-Catenin (RUO)

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD34

DNA-protein interactions are studied by using ChIP. The basic steps in this technique are crosslinking, sonication, immunoprecipitation, and analysis of the immunoprecipitated DNA. During ChIP, if chromatin is under-fragmented or fragments are too large which can lead to the increased background and lower resolution. Shorter cross-linking times (5-10 min) and/or lower formaldehyde concentrations (<1%) may improve shearing efficiency. If Chromatin is over-fragmented, then optimize shearing conditions for each cell type to improve ChIP efficiency. Over-sonication of chromatin may disrupt chromatin integrity and denature antibody epitopes. If you do not see any product or very little product in the input PCR reactions, add 5–10 μg chromatin per IP.

Proteins ChIP Mouse CD4+ T

Get tips on using Tlr4 Mouse siRNA Oligo Duplex to perform siRNA / miRNA gene silencing Mouse - BV2 TLR4

Products OriGene Tlr4 Mouse siRNA Oligo Duplex

Get tips on using ON-TARGETplus Mouse Lgals3 siRNA to perform siRNA / miRNA gene silencing Mouse - BV2 LGAL3S3

Products Dharmacon ON-TARGETplus Mouse Lgals3 siRNA

Get tips on using ON-TARGETplus Mouse Samhd1 siRNA to perform siRNA / miRNA gene silencing Mouse - BMDMs SAMHD1

Products Dharmacon ON-TARGETplus Mouse Samhd1 siRNA

Get tips on using ON-TARGETplus Mouse Stat3 siRNA to perform siRNA / miRNA gene silencing Mouse - RAW264.7 STAT3

Products Dharmacon ON-TARGETplus Mouse Stat3 siRNA

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms