siRNA / miRNA gene silencing Human Min-6

- Found 6917 results

Get tips on using Image-IT™ LIVE Green Reactive Oxygen Species Detection Kit, for microscopy to perform ROS assay cell type - H9c2 rat cardiomyocytes

Products Thermo Fisher Scientific Image-IT™ LIVE Green Reactive Oxygen Species Detection Kit, for microscopy

Get tips on using PureLink™ HiPure Plasmid Filter Purification Kits - for Midi and Maxi preparation of Plasmid DNA to perform Plasmid Isolation Citrobacter koseri

Products Thermo Fisher Scientific PureLink™ HiPure Plasmid Filter Purification Kits - for Midi and Maxi preparation of Plasmid DNA

Get tips on using Corning™ Basal Cell Culture Liquid Media - DMEM and Ham's F-12, 50/50 Mix to perform Mammalian cell culture media HSG cells

Products Fisher Scientific Corning™ Basal Cell Culture Liquid Media - DMEM and Ham's F-12, 50/50 Mix

ROS has a very short half-lives in biological environment as they are influenced by exposure to ambient oxygen. As it is highly reactive and hard to measure care should be taken to ensure the stability of the sample during isolation, preparation, storage, and analysis.

Cellular assays ROS assay cell type MiaPaCa-2 pancreatic carcinoma

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Mouse C2C12 miR-145 target site

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Mouse Point mutation C2C12 miR-145

Protein ladders are a set of standards known as molecular weight proteins that are utilized to identify the approximate size of a protein molecule run on a PAGE gel electrophoresis. The challenges in running the ladders are the choice of appropriate protein standard as it is used as visual evidence of protein migration, transfer efficiency, and positive control. Suitable protein markers can be selected on the basis of required properties and applications, i.e., fluorescent ladder, IEF, 2D SDS-PAGE ladder, natural ladder with an isoelectric point, and optimized ladders for Western Blot chemiluminescence detection. The key factors for running a distinct protein ladder are buffer conditions, charge/voltage at migration time, and the gel's concentration.

Proteins Protein Ladder Prestained

Protein ladders are a set of standards known as molecular weight proteins that are utilized to identify the approximate size of a protein molecule run on a PAGE gel electrophoresis. The challenges in running the ladders are the choice of appropriate protein standard as it is used as visual evidence of protein migration, transfer efficiency, and positive control. Suitable protein markers can be selected on the basis of required properties and applications, i.e., fluorescent ladder, IEF, 2D SDS-PAGE ladder, natural ladder with an isoelectric point, and optimized ladders for Western Blot chemiluminescence detection. The key factors for running a distinct protein ladder are buffer conditions, charge/voltage at migration time, and the gel's concentration.

Proteins Protein Ladder Immunofluorescence

Protein ladders are a set of standards known as molecular weight proteins that are utilized to identify the approximate size of a protein molecule run on a PAGE gel electrophoresis. The challenges in running the ladders are the choice of appropriate protein standard as it is used as visual evidence of protein migration, transfer efficiency, and positive control. Suitable protein markers can be selected on the basis of required properties and applications, i.e., fluorescent ladder, IEF, 2D SDS-PAGE ladder, natural ladder with an isoelectric point, and optimized ladders for Western Blot chemiluminescence detection. The key factors for running a distinct protein ladder are buffer conditions, charge/voltage at migration time, and the gel's concentration.

Proteins Protein Ladder Unstained

Western blotting is a widely used technique to size separate proteins from a pool of cell or tissue lysates. The technique has 4 major steps: a) gel electrophoresis, b) blocking and treatment with antigen specific antibody, c) treatment with secondary antibody and finally d) detection and visualization. Though western blotting is a widely used technique, detection of specific proteins depends on several factors, the major ones are antibody concentration, incubation time and washing steps. Key points for obtaining clean blots are: always prepare fresh buffer solutions and optimize antibody concentration. Given the advent of high-throughput protein analysis and a push to limit the use of lab consumables, onestep antibodies are developed which recognise protein of interest and also contain a detection label.

Proteins Western blotting β₂ microglobulin

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms