DNA methylation profiling Gene specific profiling MRC-5

- Found 5468 results

As autophagy is a multi-step process which includes not just the formation of autophagosomes, but most importantly, flux through the entire system, including the degradation upon fusion with lysosomes, which makes it quite challenging for detection. There are several methods for detection in mammalian cells, including immunoblotting analysis of LC3 and p62 and detection of autophagosome formation/maturation by fluorescence microscopy, Currently, there is no single “gold standard” for determining the autophagic activity that is applicable in every experimental context, hence it is recommended to go for the combined use of multiple methods to accurately assess the autophagic activity in any given biological setting.

Cellular assays Autophagy assay cell type N27 dopaminergic cells

As autophagy is a multi-step process which includes not just the formation of autophagosomes, but most importantly, flux through the entire system, including the degradation upon fusion with lysosomes, which makes it quite challenging for detection. There are several methods for detection in mammalian cells, including immunoblotting analysis of LC3 and p62 and detection of autophagosome formation/maturation by fluorescence microscopy, Currently, there is no single “gold standard” for determining the autophagic activity that is applicable in every experimental context, hence it is recommended to go for the combined use of multiple methods to accurately assess the autophagic activity in any given biological setting.

Cellular assays Autophagy assay cell type Proximal tubular cells (rPT)

As autophagy is a multi-step process which includes not just the formation of autophagosomes, but most importantly, flux through the entire system, including the degradation upon fusion with lysosomes, which makes it quite challenging for detection. There are several methods for detection in mammalian cells, including immunoblotting analysis of LC3 and p62 and detection of autophagosome formation/maturation by fluorescence microscopy, Currently, there is no single “gold standard” for determining the autophagic activity that is applicable in every experimental context, hence it is recommended to go for the combined use of multiple methods to accurately assess the autophagic activity in any given biological setting.

Cellular assays Autophagy assay cell type RPE-J cells

ROS has a very short half-lives in biological environment as they are influenced by exposure to ambient oxygen. As it is highly reactive and hard to measure care should be taken to ensure the stability of the sample during isolation, preparation, storage, and analysis.

Cellular assays ROS assay cell type MCF-7

Cell cycle can be challenging due to difference introduced by sample handling, timing, and difference within the sample. Downstream instriuments to analyse cell cycle (Multicolor flow cytometry and multicolor imaging) can answer these challenges. Relevant markers can be combined with cell phenotyping markers to look at events within subpopulations of cells.

Cellular assays Cell cycle assay human MCF-7

Cell cycle can be challenging due to difference introduced by sample handling, timing, and difference within the sample. Downstream instriuments to analyse cell cycle (Multicolor flow cytometry and multicolor imaging) can answer these challenges. Relevant markers can be combined with cell phenotyping markers to look at events within subpopulations of cells.

Cellular assays Cell cycle assay human MCF 10A

Cell Invasion or Cell Migration assays are technically challenging to set up as the gradient between the two compartments equilibrates in time during the assay. It is also problematic to view cells and for cells to migrate through a non-physiologic polycarbonate or polypropylene filter. Care must be taken while loading the well with cells to form a single cell suspension. Precaution must be taken while trypsinization (under-trypsinization can lead to cell clumping while over-trypsinization could strip off adhesion molecules necessary for migration). This leads to difficulty in getting significant results, when only small numbers of cells cross the filter or when the distribution and/or staining of the cells is uneven.

Cellular assays Cell migration / Invasion cell type MCF7

Cell Invasion or Cell Migration assays are technically challenging to set up as the gradient between the two compartments equilibrates in time during the assay. It is also problematic to view cells and for cells to migrate through a non-physiologic polycarbonate or polypropylene filter. Care must be taken while loading the well with cells to form a single cell suspension. Precaution must be taken while trypsinization (under-trypsinization can lead to cell clumping while over-trypsinization could strip off adhesion molecules necessary for migration). This leads to difficulty in getting significant results, when only small numbers of cells cross the filter or when the distribution and/or staining of the cells is uneven.

Cellular assays Cell migration / Invasion cell type MCF-10A
EMBacY#6 Product

Get tips on using EMBacY#6 to perform Protein Expression Eukaryotic cells - Hi5 mCSF1

Products Sabine Suppmann, Max-Planck Institute of Biochemistry EMBacY#6

Get tips on using TRIzol Reagent to perform RNA isolation / purification Cells - immortalized MCF-7

Products Thermo Fisher Scientific TRIzol Reagent

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms