Cell cycle assay

- Found 6949 results

Get tips on using CellTiter 96® AQueous One Solution Cell Proliferation Assay (MTS) to perform Cell cytotoxicity / Proliferation assay cell type - SH-SY5Y

Products Promega CellTiter 96® AQueous One Solution Cell Proliferation Assay (MTS)

Get tips on using CellTiter 96® AQueous One Solution Cell Proliferation Assay (MTS) to perform Cell cytotoxicity / Proliferation assay cell type - L-02

Products Promega CellTiter 96® AQueous One Solution Cell Proliferation Assay (MTS)

TUNEL assay is the cell death detection method where the biochemical marker of apoptosis is DNA fragmentation. The assay involves the microscopical detection of generated DNA fragments with free 3'-hydroxyl residues. in apoptotic cells using enzyme terminal deoxynucleotidyl transferase (TdT) which adds biotinylated nucleotides at the site of DNA breaks. Major challenges of this method involve proper access of the enzyme which could be hampered by poor permeabilization and/or excessive fixation with cross-linking fixative (common with archival tissue). This issue can be resolved by optimizing the incubation time with Proteinase K or CytoninTM.

Cellular assays TUNEL assay cell type A127, U87MG, U251MG, T98G human glioblastoma cells

Get tips on using CellTiter 96® AQueous One Solution Cell Proliferation Assay (MTS) to perform Cell cytotoxicity / Proliferation assay cell type - LTEP-a-2 lung adenocarcenoma

Products Promega CellTiter 96® AQueous One Solution Cell Proliferation Assay (MTS)

TUNEL assay is the cell death detection method where the biochemical marker of apoptosis is DNA fragmentation. The assay involves the microscopical detection of generated DNA fragments with free 3'-hydroxyl residues. in apoptotic cells using enzyme terminal deoxynucleotidyl transferase (TdT) which adds biotinylated nucleotides at the site of DNA breaks. Major challenges of this method involve proper access of the enzyme which could be hampered by poor permeabilization and/or excessive fixation with cross-linking fixative (common with archival tissue). This issue can be resolved by optimizing the incubation time with Proteinase K or CytoninTM.

Cellular assays TUNEL assay cell type A549, NCI-H460, H1299 human alveolar carcinoma

ROS has a very short half-lives in biological environment as they are influenced by exposure to ambient oxygen. As it is highly reactive and hard to measure care should be taken to ensure the stability of the sample during isolation, preparation, storage, and analysis.

Cellular assays ROS assay cell type BEAS-2B human bronchial epithelial cell line

A gross majority of classical apoptotic attributes can be quantitatively examined by flow cytometry, the preferred platform for rapid assessment of multiple cellular attributes at a single-cell level. However, sample preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Apoptosis assay cell type T-cells Mouse (CD4+ and CD8+)

Get tips on using QCM™ Tumor Cell Transendothelial Migration Assay (Colorimetric, 24 Assays) to perform Cell migration / Invasion cell type - SW480

Products Merck Millipore QCM™ Tumor Cell Transendothelial Migration Assay (Colorimetric, 24 Assays)

Get tips on using CytoSelect™ 24-Well Cell Migration Assay, 8 μm to perform Cell migration / Invasion cell type - BCPAP

Products Cell Biolabs CytoSelect™ 24-Well Cell Migration Assay, 8 μm

Get tips on using CytoSelect™ 24-Well Cell Migration Assay, 8 μm to perform Cell migration / Invasion cell type - SW480

Products Cell Biolabs CytoSelect™ 24-Well Cell Migration Assay, 8 μm

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms