Get tips on using ON-TARGETplus Mouse Casp8 (12370) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Mouse - CT26 caspase-8
Get tips on using Anti-Clara Cell Secretory Protein Antibody to perform Flow cytometry Anti-bodies Mouse - CCSP
Get tips on using ON-TARGETplus Mouse Hspa5 (14828) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Mouse - MC3T3-E1 Grp78/Hspa5
Get tips on using ON-TARGETplus Mouse Mapk1 (26413) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Mouse - MC3T3-E1 MAPK1 (ERK2)
Get tips on using ON-TARGETplus Mouse Mapk14 (26416) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Mouse - MC3T3-E1 p38/Mapk14
Get tips on using ON-TARGETplus Mouse Nr1h3 (22259) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Mouse - M210B4 LXR‐α/Nr1h3
Get tips on using ON-TARGETplus Mouse Nr1h2 (22260) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Mouse - M210B4 LXR‐β/Nr1h2
Get tips on using ON-TARGETplus Mouse Zbp1 (58203) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Mouse - 3T3-SA Zbp1/Dai
ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.
ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment