RNA isolation / purification Tissue Mouse

- Found 7068 results

ROS has a very short half-lives in biological environment as they are influenced by exposure to ambient oxygen. As it is highly reactive and hard to measure care should be taken to ensure the stability of the sample during isolation, preparation, storage, and analysis.

Cellular assays ROS assay cell type PC-3 human prostate adenocarcinoma

ROS has a very short half-lives in biological environment as they are influenced by exposure to ambient oxygen. As it is highly reactive and hard to measure care should be taken to ensure the stability of the sample during isolation, preparation, storage, and analysis.

Cellular assays ROS assay cell type PANC-, BxPC-3 human pancreas

Get tips on using Quick Amp Labeling Kit-one color to perform RNA amplification & labeling Mammalian - miRNA, Human Endometrial Stromal cells Cyanine 3-pCp

Products Agilent Technologies Quick Amp Labeling Kit-one color

ROS has a very short half-lives in biological environment as they are influenced by exposure to ambient oxygen. As it is highly reactive and hard to measure care should be taken to ensure the stability of the sample during isolation, preparation, storage, and analysis.

Cellular assays ROS assay cell type BEAS-2B human bronchial epithelial cell line

ROS has a very short half-lives in biological environment as they are influenced by exposure to ambient oxygen. As it is highly reactive and hard to measure care should be taken to ensure the stability of the sample during isolation, preparation, storage, and analysis.

Cellular assays ROS assay cell type A549 human adenocarcinomic human alveolar basal epithelial cells

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells human Mesenchymal stem cells

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells bmMSCs human bone marrow

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells FE002-SK2 human skin progenitor cells

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells MCF-7 human breast cancer cells

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells HepaRG human hepatoma

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms